Downloading Parameters from the SY-253 Board

1-1. Precautions

. Contents of this installation manual premises that the replacement of the circuit board using the
BKMA-U70XGI and the version upgrade in order to increase capacity of hard disks such as the
BKMA-U70/36 are going to be implemented simultaneously.
Note that all the materials that have already been stored in the hard disks will be erased when the hard
disks are upgraded of the version.
When the circuit board is replaced using the BKMA-U70XGI, the data that have been stored in the SY-
253 board must be downloaded and then be uploaded to the SY-253A board in order to transfer the
data.
. Shut down the system and turn off the main power of the MAV-70 before starting the circuit board
replacement work using the BKMA-U70XGI.

1-2. Equipment Required

(The software TeraTermPro and the data downloading program are contained in the CD-ROM supplied.)
. Personal computer (Windows95/98/2000/NT4.0)
. RS-232C cross cable
. TeraTermPro (Version 2.3)
. GetSyPr10.ttl (SY253 Data Download Macro)
n
The CD-ROM supplied, contains the following files.
. GetSyPr10.ttl (SY253 DataDownload Macro)
. PutSyPr10. (SY253 DataUpload Macro)
. VfySyPr10.ttl (SY253 Data Verify Macro)
Cables
Connectors on a personal computer side
D-sub 9-pin, male
Connectors on a MAV-70 side
D-sub 9-pin, female
. Personal computer side
1
2
RXD
3
TXD
4
5
GND
6
7
8
9
(D-sub 9-pin, male)
BKMA-U70XGI
Section 1
1-560-651-00 (connector)
1-561-749-00 (shell)
1-562-565-00 (connector)
1-561-749-00 (shell)
. MAV-70 side
NC
RXD
TXD
NC
GND
NC
NC
NC
NC
(D-sub 9-pin, female)
1
2
3
4
5
6
7
8
9
1-1 (E)