Uploading Parameters To The Sy-253A Board; Equipment Required - Sony BKMA-U70XGI Manual

Upgrade kit for mav-70
Table of Contents

Advertisement

Section 4

Uploading Parameters to the SY-253A Board

This section describes the procedure to upload the original parameters that are downloaded from the
previous SY-253 board in Section 1, to the SY-253A board.

4-1. Equipment Required

(The software TeraTermPro and the parameter uploading program are contained in the CD-ROM
supplied.)
. Personal computer (Windows95/98/2000/NT4.0)
. RS-232C cross cable
. TeraTermPro (Version 2.3)
. PutSyPr10.ttl (SY253 DataUpload Macro)
4-2. Uploading Parameters to the SY-253A Board
1. Remove the ornamental panel (A) from the MAV-70.
(Refer to Section 2-2-1 of the Maintenance Manual Volume 1.)
2. Set the switch S3 on the front panel of the MAV-70 to INT.
Switch S3
3. Connect the MAV-70 to a personal computer with the RS-232C cross cable.
Personal computer
RS-232C cable (9P-9P)
COM1
4-1 (E)
BKMA-U70XGI