Entering Diagnostics - KVH Industries TracPhone V7 Replacement Instructions

Pcb replacement
Hide thumbs Also See for TracPhone V7:

Advertisement

TracPhone V7
PCB Replacement Instructions
Step 2 - Calibrate the Gyro
4
Follow the steps below to calibrate the gyros for use with the new PCB.
IMPORTANT!
To perform this calibration, the vessel must remain stationary in
calm seas.
a. Apply power to the TracPhone V7 modem and control
unit and turn on the system. Wait five minutes for
system startup.
b. Using the control unit, press
display shows "DIAGNOSTICS."
DIAGNOSTICS
NEXT MENU
c. Press
ACCEPT to enter the Diagnostics menu.

ENTERING DIAGNOSTICS

CAL GYRO= NO
NEXT ITEM
d. Press
CHANGE until the display shows "CAL
GYRO= YES."
CAL GYRO= YES?
CHANGE
MENUS until the
ACCEPT
CHANGE
ACCEPT