ETAS ES5371.1 User Manual

For es4435 load boards

Advertisement

Quick Links

ES5371.1 Carrier Board for ES4435 Load Boards
User's Guide

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ES5371.1 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for ETAS ES5371.1

  • Page 1 ES5371.1 Carrier Board for ES4435 Load Boards User’s Guide...
  • Page 2 The data in this document may not be altered or amended without special noti- fication from ETAS GmbH. ETAS GmbH undertakes no further obligation in rela- tion to this document. The software described in it can only be used if the customer is in possession of a general license agreement or single license.
  • Page 3: Table Of Contents

    2.3.2 Inserting the ES5371.1 into the Slot......19 3 Pin Assignment and Connections ........21 Backplane Connector (CO402) .
  • Page 4 5 ETAS Contact Addresses ........
  • Page 5: Introduction

    ETAS Introduction Introduction This User’s Guide describes the ES5371.1 Carrier Board for ES443x Load Boards. CAUTION! Some components of the ES5371.1 Carrier Board for ES443x Load Boards may be damaged or even destroyed by static discharge. Leave the board in its transport package until you want to install it.
  • Page 6: Features

    Introduction ETAS Features The ES5371.1 Carrier Board for ES443x Load Boards is used to accommodate ETAS ES443x Load Boards. Fig. 1-1 Front Panel and Rear of the ES5371.1 The ES5371.1 Carrier Board for ES443x Load Boards comes without a Load Board.
  • Page 7: Fig. 1-3 Es5371.1 Carrier Board For Es443X Load Boards (With Es4435.1)

    ETAS Introduction Fig. 1-3 shows the ES5371.1 Carrier Board for ES443x Load Boards holding an ES4435.1 Current Source Load Board (ETAS order number F-00K-106-163). For more details on the ES4435.1 Current Source Load Board, please refer to the "ES4435.1 Current Source Load Board – User’s Guide".
  • Page 8: Basic Safety Instructions

    The ES5371.1 Carrier Board for ES443x Load Boards is not protected against the polarity of the UBatt voltages being mistaken! To protect the UBatt voltage, there are two fuses on the ES5371.1. The ES4435.1 Current Source Load Board is protected against the polarity of the UBatt voltage being mistaken.
  • Page 9: Transport And Installation

    Please take the following precautionary measures to avoid any injuries and dam- age to hardware: • Do not apply any voltages to the ports of the ES5371.1 Carrier Board for ES443x Load Boards which do not correspond to the specifications of the relevant port.
  • Page 10 ES5300 System Housing and cannot be integrated here. The ES5371.1 may only be installed and operated in an ES5300 System Housing. The ES5371.1 in an ES5300 System Housing is intended to be used as follows • In industrial lab facilities or at industrial workplaces, •...
  • Page 11: Identifications On The Product

    1.5.1 European Union The EU Directive 2002/95/EU limits the use of certain dangerous materials for electrical and electronic devices (RoHS conformity). ETAS confirms that the product corresponds to this directive which is applicable in the European Union. 1.5.2 China ETAS confirms that the product meets the product-specific applicable guidelines...
  • Page 12: Taking The Product Back And Recycling

    The user is obliged to collect the old devices separately and return them to the WEEE take-back system for recycling. The WEEE Directive concerns all ETAS devices but not external cables or batteries. For more information on the ETAS GmbH Recycling Program, contact the ETAS sales and service locations (see "ETAS Contact Addresses"...
  • Page 13: About This Manual

    This section describes the various connectors of the ES5371.1 Carrier Board for ES443x Load Boards. • "Technical Data" on page 27 This chapter contains the technical data on the ES5371.1 Carrier Board for ES443x Load Boards. 1.7.1 Using This Manual Representation of Information All activities to be carried out by the user are shown in what we call a "Use-...
  • Page 14 Content markings and newly introduced logical and arithmetic is not possi- terms are shown in italics ble. Important notes for the user are shown as follows: Note Important note for the user. ES5371.1 Carrier Board for ES443x Load Boards - User’s Guide...
  • Page 15: Features And Functions

    – "Inserting the ES5371.1 into the Slot" on page 19 Power Supply Power is supplied to the ES5371.1 Carrier Board for ES443x Load Boards and accommodated load boards via the backplane of the ES5300.1-A. The CO402 connector (see Fig. 2-1) is responsible for the electrical connection.
  • Page 16: Fuses

    Features and Functions ETAS Fuses There are five fuses on the ES5371.1 Carrier Board for ES443x Load Boards to protect the backplane voltages. The battery voltage is protected using two sepa- rate fuses. Fig. 2-2 Fuse Positions Fuse Type Specification...
  • Page 17: Assembling The Es443X Load Boards

    The ES4435.1 Current Source Load Board is used below as an example of how to assemble a load board. Before the ES4435.1 can be assembled on the ES5371.1, the front panel of the ES4435.1 has to be removed. • Remove the front panel of the ES4435.1 by loosen- ing the assembly bracket from the board (see Fig.
  • Page 18: Assembling The Es5371.1 In The Es5300.1-A Housing

    Boards may be damaged or even destroyed by static discharge. Leave the board in its transport package until you want to install it. The ES5371.1 Carrier Board for ES443x Load Boards should only be taken from its package, configured and installed at a working place that is protected against static discharge.
  • Page 19: Inserting The Es5371.1 Into The Slot

    Inserting the ES5371.1 into the Slot CAUTION! Before assembling the ES5371.1 in the ES5300.1-A Housing, please ensure that the Load Board is correctly assembled in the ES5371.1! • Shut down the Real-Time PC and disconnect the power supply to the ES5300.1-A Housing by switching it off on the back of the device.
  • Page 20 Features and Functions ETAS ES5371.1 Carrier Board for ES443x Load Boards - User’s Guide...
  • Page 21: Pin Assignment And Connections

    ETAS Pin Assignment and Connections Pin Assignment and Connections This section describes the various connectors of the ES5371.1 Carrier Board for ES443x Load Boards. • "Backplane Connector (CO402)" on page 21 • "D-Sub25 (CO100)" on page 23 • "Battery Voltages (CO101)" on page 24 •...
  • Page 22 BN_4 BN_5 n.c. n.c. n.c. n.c. n.c. n.c. 12-Shield SPI_CS_A_n SPI_CS_B_n n.c. n.c. n.c. n.c. n.c. n.c. 11-Shield SPI_CLK SPI_MOSI n.c. n.c. n.c. n.c. n.c. n.c. 10-Shield SPI_MISO PCIE_WAKEn n.c. n.c. n.c. n.c. n.c. n.c. 9-Shield n.c. n.c. n.c. n.c. n.c.
  • Page 23: D-Sub25 (Co100)

    Current Source 8 Current Source 21 Current Source 9 Current Source 22 Current Source 10 Current Source 23 Current Source 11 –UBatt Current Source 12 Tab. 3-1 Pin Assignment for ES4435.1 Assembly ES5371.1 Carrier Board for ES443x Load Boards - User’s Guide...
  • Page 24: Battery Voltages (Co101)

    Tab. 3-2 CO101 Pin Assignment CAUTION! The ES5371.1 Carrier Board for ES443x Load Boards is not protected against the polarity of the UBatt voltage being mistaken. There are two fuses for protecting the UBatt voltage on the ES5371.1. The ES4435.1 Current Source Load Board is protected against the polarity of the UBatt voltage being mistaken.
  • Page 25: Connectors For Es443X Load Boards (Co200)

    ETAS Pin Assignment and Connections Connectors for ES443x Load Boards (CO200) The CO200 connector is the electrical interface between the ES5371.1 Carrier Board for ES443x Load Boards and the ES443x.1 Load Boards. Fig. 3-4 CO200 Pin Assignment CAUTION! The "CO200" can only be used with ES443x.y products by ETAS.
  • Page 26 Not assigned Not assigned Not assigned Not assigned Not assigned Not assigned SPI MISO SPI MOSI SPI CLK VCC5V VCC24V VCC3,3V VDD12V VSS-12V Tab. 3-3 CO200 Pin Assignment ES5371.1 Carrier Board for ES443x Load Boards - User’s Guide...
  • Page 27: Technical Data

    ETAS Technical Data Technical Data This chapter contains the technical data on the ES5371.1 Carrier Board for ES443x Load Boards. Voltages, Currents and Power Consumption Maximum voltage at inputs and outputs (CO100) 60 V Maximum current per individual contact of the input/output...
  • Page 28: Fulfilled Standards And Norms

    WARNING! This is a Class-A device. This device can cause radio interference in residential environments. In this case, the operator can be required to take appropriate measures. ES5371.1 Carrier Board for ES443x Load Boards - User’s Guide...
  • Page 29: Etas Contact Addresses

    For details of your local sales office as well as your local technical support team and product hotlines, take a look at the ETAS website: ETAS subsidiaries WWW: www.etas.com/en/contact.php ETAS technical support WWW: www.etas.com/en/hotlines.php ES5371.1 Carrier Board for ES443x Load Boards - User’s Guide...
  • Page 30 ETAS Contact Addresses ETAS ES5371.1 Carrier Board for ES443x Load Boards - User’s Guide...
  • Page 31: Figures

    Connector to the Backplane of the ES5300.1-A (Plug-In Side) ..... 21 Fig. 3-2 D-Sub25 Port for Signals................23 Fig. 3-3 Plug on ES5371.1 (Left) and Female Connector with Gripping Plate (Right) . 24 Fig. 3-4 CO200 Pin Assignment................25 ES5371.1 Carrier Board for ES443x Load Boards - User’s Guide...
  • Page 32 Figures ETAS ES5371.1 Carrier Board for ES443x Load Boards - User’s Guide...
  • Page 33: Index

    RoHS conformity Devices China 11 connecting 9 European Union 11 Electrical safety 10 Safety instructions 8 Environmental conditions 27 Safety instructions, labeling 8 ETAS Contact Addresses 29 Standards and norms 28 ES5371.1 Carrier Board for ES443x Load Boards - User’s Guide...