Reece Kado Aspect Installation Instructions Manual

Flush mount inline exhaust

Advertisement

Quick Links

Kado Aspect Flush Mount Inline Exhaust
Please read these instructions carefully before installing and using the product. Keep the instructions handy for future reference.
Electrical wiring must only be done by a licensed electrician and a "Certificate of Compliance" must be issued on completion of the
WHAT'S IN THE BOX
• Inline Exhaust Fan.
• Intake Fascia.
• Outlet Grille .
• 6m x Ø150mm Aluminium Ducting.
• Operating and Installation Instructions.
• Cutout Template.
• 4 Cable ties for attaching duct.

SAFETY INSTRUCTIONS

During use of the product, it is necessary to observe some precautions. Improper operation with disregard of precautions may result in
infliction of harm to health of the user and other people, as well as infliction of damage to their property.
• Use only the voltage specified on the rating plate of the fan.
• This item should only be installed by a licensed tradesperson.
• The fan should be connected to the electric mains equipped with an automatic circuit breaker.
• The unit must be handled with care avoiding any sudden impacts or vibrations.
WARNING: DO NOT CONNECT POWER SUPPLY UNTIL FAN IS COMPLETELY INSTALLED. MAKE SURE ELECTRICAL
• Read all instructions before installing or using exhaust fan.
• If the fan is defective, it must be checked and repaired by the manufacturer, its service agent or similarly qualified persons for repair.
• Do not operate appliance with wet hands.
• Use this appliance only as described in this manual. Any other use is not recommended by the manufacturer and may cause fire,
electric shock or injury.
• Do not use abrasive cleaning products on this appliance. If the body becomes dirty, wipe off dust with a cloth. Always remove plug
from the mains supply before cleaning.
• Do not connect the appliance to the mains source until it has been installed in its final location and adjusted to the position it will be
used in.
• Do not operate with the cord coiled up as this could cause a build-up of heat, which could pose a hazard.
• The use of an extension cord with this appliance is not recommended.
• This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack
of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person
responsible for their safety.
• Children should be supervised to ensure that they do not play with the appliance
• The appliance is only intended for the purpose described in user manual.
• Do not use appliance or any part of the appliance out of the intended use to avoid risk.
• The use of attachments which are not recommended or sold by the appliance manufacturer may cause a risk of injury to persons.
• CAUTION — For general ventilation use only. Do not use to exhaust hazardous or explosive materials and vapors.
Electricians, please ensure a copy of the Installation
Instructions are left with the end user for future reference
SERVICE TO THE FAN IS LOCKED IN AN OFF POSITION.
Installation Instructions
Page 1 of 6

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Kado Aspect and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Reece Kado Aspect

  • Page 1 Installation Instructions Kado Aspect Flush Mount Inline Exhaust Please read these instructions carefully before installing and using the product. Keep the instructions handy for future reference. Electrical wiring must only be done by a licensed electrician and a “Certificate of Compliance” must be issued on completion of the installation.
  • Page 2 Installation Instructions Kado Aspect Flush Mount Inline Exhaust • To protect against the risk of electrical shock, do not immerse the unit, cord or plug in water or other liquid. • When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.
  • Page 3 Installation Instructions Kado Aspect Flush Mount Inline Exhaust INSTALLING THE FAN CAUTION: MAKE SURE POWER IS SWITCHED OFF AT THE SERVICE PANEL BEFORE STARTING INSTALLATION. 1. This exhaust fan is fitted with a supply cable and plug. There is no need to open the fan for wiring. The location of installation must be near a socket outlet.
  • Page 4 Installation Instructions Kado Aspect Flush Mount Inline Exhaust INSTALLATION 4. To start the installation, the motor wheel assembly must first be removed. Loosen the two spring clips around the casing and remove. (Diagrams 1-3 below) 5. Secure the mounting bracket fan flange assembly to a fixed structure. (Diagrams 4-5 below) NOTE: To maximise fan performance, install as near to air outlet point as possible.
  • Page 5 Installation Instructions Kado Aspect Flush Mount Inline Exhaust ELECTRICAL CONNECTION WARNING: All electrical work must be carried out by a licensed electrician. All electrical wiring must be in accordance with the latest national wiring rules AS/NZS 3000. WARNING: Ensure the power supply to the exhaust fan is switched OFF before carrying out any installation and maintenance.
  • Page 6 Installation Instructions Kado Aspect Flush Mount Inline Exhaust INSTALLING THE FLUSH MOUNT FASCIA KIT 1. Locate a suitable location for the Flush Mount Fascia. Use the template card provided for marking the cut-out hole. 2. Cut a rectangle hole 583 x 153mm into the vents mounting surface.

Table of Contents