NPort P5150A Series
Quick Installation Guide
Moxa Americas:
Toll-free: 1-888-669-2872
Tel:
1-714-528-6777
Fax:
1-714-528-6778
Moxa Europe:
Tel:
+49-89-3 70 03 99-0
Fax:
+49-89-3 70 03 99-99
Moxa India:
Tel:
+91-80-4172-9088
Fax:
+91-80-4132-1045
Edition 2.1, November 2018
Technical Support Contact Information
www.moxa.com/support
 2018 Moxa Inc. All rights reserved.
Moxa China (Shanghai office):
Toll-free: 800-820-5036
Tel:
+86-21-5258-9955
Fax:
+86-21-5258-5505
Moxa Asia-Pacific:
Tel:
+886-2-8919-1230
Fax:
+886-2-8919-1231
P/N: 1802052000313
*1802052000313*

Advertisement

loading

Summary of Contents for Moxa Technologies NPort P5150A Series

  • Page 1 NPort P5150A Series Quick Installation Guide Edition 2.1, November 2018 Technical Support Contact Information www.moxa.com/support Moxa Americas: Moxa China (Shanghai office): Toll-free: 1-888-669-2872 Toll-free: 800-820-5036 Tel: 1-714-528-6777 Tel: +86-21-5258-9955 Fax: 1-714-528-6778 Fax: +86-21-5258-5505 Moxa Europe: Moxa Asia-Pacific: Tel: +49-89-3 70 03 99-0...
  • Page 2: Package Checklist

    Notify your sales representative if any of the above items are missing or damaged. Hardware Introduction As shown in the following figures, NPort P5150A series of device servers have one male DB9 port for transmitting RS-232/422/485 serial data. Reset Button—Press and hold the Reset button for 5 seconds to load factory defaults: Use a pointed object, such as a straightened paper clip or toothpick, to depress the reset button.
  • Page 3 WARNING 1. The equipment is designed for in-building installation only and is not intended to be connected to exposed (outside plant) networks. 2. This equipment is intended to be used in a Restricted Access Location. 3. This product is intended to be supplied by an UL60950-1 and IEC60950-1 certified Power Unit marked “LPS”...
  • Page 4: Hardware Installation Information

    Hardware Installation Information STEP 1: After removing the NPort P5150A device server from the box, if you are not using a PoE switch, the first thing you should do is connect the power adaptor. STEP 2: Connect the NPort P5150A device server to a network. Use a standard straight-through Ethernet cable to connect to a PoE switch.
  • Page 5: Pin Assignments

    Pin Assignments Ethernet Port Pinouts Pin No. Ethernet NPort P5150A—DB9 male (RS-232/422/485) port pinouts Pin No. RS-232 RS-422/485-4W RS-485-2W TxD-(A) – TxD+(B) – RxD+(B) Data+(B) RxD-(A) Data-(A) – – – – – – – – – Specifications Power Requirements Power Input 12 to 48 VDC (Supplied by power adapter) or 48 VDC (Supplied by PoE.) Power Consumption...