Item
Description
St
Temperature set-point
Po
Administrator menu password
C1
Differential
Compressor start delay between
C2
last switch-off and the successive
switch-on
Compressor start delay after
C3
switch-on of the device
Calibration temperature 1.
C4
Temperature value added to the
value read by cabinet sensor
Low set-point. Minimum possible
C5
set-point
High set-point. Maximum possible
C6
set-point
Maximum standby time after
C7
compressor start delay①
C8
Minimum compressor on time
d1
Evaporator sensor options
Calibration temperature 2. The
temperature value added to the
d2
value read by the evaporator
sensor.
d3
Defrost counting type
d4
Defrost interval time
d5
Display during defrost
d6
Maximum defrost duration

PARAMETER TABLE

User Menu
Low set-point~High set-point
00~99(Default password is 55 and
unchangeable)
Administrator Menu
0.5℃~9.0℃
1℉~20℉
0~60
0~90
-10.0℃~10.0℃
-20℉~20℉
-50℃ ~Temperature set-point
-58℉ ~Temperature set-point
Temperature set-point ~ -85℃
Temperature set-point ~ -185℉
0~90
0: Disabled
0~90
0: Disabled
0: Disable
1: Enable
-10.0℃~10.0℃
-20℉~20℉
0: Compressor operating time
1: Controller power-on time
0~90
0: Disable defrost
0: Displays cabinet temperature;
1: Displays dEF during defrost and d9,
displays cabinet temperature after d9
elapses;
2: Displays dEF during defrost and
dripping;
3. Displays cabinet temperature at defrost
start during defrost and dripping.
4.
1~90
Setting Range
13
Default
Unit
℃/℉
4℃
00
/
℃/℉
4℃
5
min
5
min
℃/℉
0.0℃
℃/℉
-2℃
℃/℉
22℃
9
min
0
min
0
/
℃/℉
0.0℃
1
/
2
hour
2
/
25