INSTRUCTION MANUAL ECOSOFT
12
Activate or deactivate regeneration on Sunday night using ▲ or ▼ buttons. Regeneration on this
day will be performed if arrow is displayed against Regen
Similarly, activate or deactivate regeneration on Monday night using ▲ or ▼ buttons. Regeneration
on this day will be performed if arrow is displayed against Regen.
Scroll over all days of the week and select days for regeneration, then exit menu.
If the control valve is configured to regenerate once in 1...99 days, this option will be shown instead
of 1 week regeneration schedule
2. Set current time by pressing SET.
See control valve manual for more information.

4. PRECAUTIONS

Remove power, shut off water supply and release pressure in the system before doing
any maintenance or repair. Protect from moisture inside parts of control valve.
Do not stress or load filter tank
• Keep track of salt in brine tank or salt compartment of cabinet. Replenish when necessary.
• To avoid fouling of media during prolonged downtime without power/water supply, fill the FRP tank
with brine as follows. Start manual regeneration, wait 20 minutes into the brine stage, then shut off
water supply and scroll regeneration cycles back to service. Then, turn off control valve.
• Perform regeneration when starting service after downtime.
• Inspect connections for leaks at least once in three months.
• Routinely check current time in control valve and correct if necessary.
• Maintain sediment prefilter regularly.
Filter cartridge must be replaced if pressure drop exceeds 1 bar (14 psi)