Advertisement

Quick Links

User Manual
Digital Thermometer PCE-T 318
User manuals in various languages (français,
italiano, español, português, nederlands, türk, polski,
русский, 中文) can be found by using our
product search on: www.pce-instruments.com
Last change: 7 February 2018
v1.0
© PCE Instruments

Advertisement

Table of Contents
loading

Summary of Contents for PCE Health and Fitness PCE-T 318

  • Page 1 User Manual Digital Thermometer PCE-T 318 User manuals in various languages (français, italiano, español, português, nederlands, türk, polski, русский, 中文) can be found by using our product search on: www.pce-instruments.com Last change: 7 February 2018 v1.0 © PCE Instruments...
  • Page 2: Table Of Contents

    Contents Safety notes ........................1 Introduction ........................2 Specifications ......................... 2 Symbol Definition and Button Location ................ 3 Operation Instructions ....................4 Power-Up ......................... 4 Connection of the temperature probe ................5 Selecting the Temperature Scale .................. 5 Data-Hold Operation ...................... 5 Back light Operation ......................
  • Page 3: Safety Notes

    Safety notes Please read this manual carefully and completely before you use the device for the first time. The device may only be used by qualified personnel and repaired by PCE Instruments personnel. Damage or injuries caused by non-observance of the manual are excluded from our liability and not covered by our warranty.
  • Page 4: Introduction

    Introduction This instrument is a digital thermometer for use with platinum-type temperature sensor. Temperature indication follows IEC751 temperature table for PT-type sensor. Specifications Numerical Display 4 digital liquid crystal display -100 °C … 300 °C; -148 °F … 572 °F Measurement Range Resolution 0.1 °C;...
  • Page 5: Symbol Definition And Button Location

    Symbol Definition and Button Location : This indicates that the minus temperature is sensed. °C °F : Centigrade and Fahrenheit indication. Pt xxx : Platinum Type Indication 4.1.1.1.1.1.1 HOLD : This indicates that the display data is being hold. MAX : The Maximum value is now being displayed MIN : The Minimum value is now being displayed AVG : The Average value is now being displayed.
  • Page 6: Operation Instructions

    ○, Pt type temperature sensor connector ○, LCD display ○, Power ON/OFF button ○, HOLD button ○, MAX MIN Average control button ○, Back light button ○, Relative readout button ○, °C , °F control button Operation Instructions Power-Up Press the ON/OFF key to turn the thermometer ON or OFF. ©...
  • Page 7: Connection Of The Temperature Probe

    Connection of the temperature probe For measurement, plug the temperature probe into the input connectors. Selecting the Temperature Scale When the meter was first power on, the default scale setting is set at Celsius (°C) scale. The user may change it to Fahrenheit (°F) by pressing “ °C/°F ” button and vice versa to Celsius. Data-Hold Operation The user may hold the present reading and keep it on the display by pressing the “HOLD”...
  • Page 8: Max/Min/Avg Operation

    MAX/MIN/AVG Operation When you press the “MAX MIN” button the meter will enter the MAX/MIN/AVG mode. Under this mode the maximum value, minimum value and average value of latest 8 data is kept in the memory simultaneously and updated with every new data. When the MAX symbol is display, the Maximum is shown on the display.
  • Page 9: Temperature Measurement

    Temperature Measurement 13.1 Correct Measurement Method The temperature sensor is located at the end of the metal sheath of the sheath type TEMPERATURE PROBE. To accurately test internal temperature insert the probe into the item you want to measure to a distance at least 15 times the diameter of the sheath. 13.2 Connector Configuration ©...
  • Page 10: Temperature Meter Calibration Setup

    Temperature Meter Calibration Setup Below table diagram shows each button function when user enter into calibration mode. Note: Turn the Power “OFF” before attempting following SETUP. Setup mode is cancelled during below procedure if “POWER” button is pressed. © PCE Instruments...
  • Page 11: Pt Type Selection

    Pt type selection Press and hold “Power” + “Light” buttons for 2 seconds to enter setup mode. Press “Hold” button to enter Pt selection mode. Press “Max” button to select between Pt probe type. (Pt100, Pt500, Pt1000 is circulate) Press “°C/°F” button to confirm selection. ©...
  • Page 12: 16 0 °C Calibration

    0 °C Calibration Press and hold “Power” + “Light” buttons for 2 seconds to enter setup mode. Press “REL” button to enter calibration mode. Enter Pt selection first. Press “°C/°F” button to confirm Pt selection Press “REL” button to enter calibration mode. ©...
  • Page 13: Recall Default Factory Setting Value

    Press “REL” button to confirm present calibration value. Press “°C/°F” button to confirm selection. Recall Default factory setting value Press and hold “Power” + “Light” buttons for 2 seconds to enter setup mode. Press “REL” button to enter calibration mode. Enter Pt selection first.
  • Page 14 Press “°C/°F” button to confirm Pt selection. Press “Light” button to enter recall mode. Press “°C/°F” button to confirm revert back to “Default factory setting value” Press “°C/°F” button to confirm selection. © PCE Instruments...
  • Page 15: Maintenance

    Maintenance 18.1 Replacing the Batteries (1) Remove back cover screw to remove cover. Verify polarity and install new LR03(AAA size) alkaline batteries. (2) Fit cover properly and tighten screw. The unit’s back cover is fitted with rubber rings. After replacing the battery, check that the rubber rings are properly seated before reinstalling the back cover.
  • Page 16: Temperature Probe

    Temperature Probe 19.1 Piercing type temperature probe 19.2 Piercing type temperature probe Specification Sensor Type Platinum resistance thermometer sensor Pt 100(4 wires) Accuracy IEC751, class A 0.15C0.002t (t: measurement temperature) Measurement Range -100 to 400C Approx. 3.2mm(0.125”) Temperature Sensor Dimensions Approx.
  • Page 17: Warranty

    Warranty You can read our warranty terms in our General Business Terms which you can find here: https://www.pce-instruments.com/english/terms. Disposal For the disposal of batteries in the EU, the 2006/66/EC directive of the European Parliament applies. Due to the contained pollutants, batteries must not be disposed of as household waste. They must be given to collection points designed for that purpose.
  • Page 18 PCE Instruments contact information Germany France Spain PCE Deutschland GmbH PCE Instruments France EURL PCE Ibérica S.L. Im Langel 4 23, rue de Strasbourg Calle Mayor, 53 D-59872 Meschede 67250 SOULTZ-SOUS-FORETS 02500 Tobarra (Albacete) Deutschland France España Tel.: +49 (0) 2903 976 99 0 Téléphone: +33 (0) 972 3537 17 Tel.

Table of Contents