Step 5, Make Electrical Connections - Monogram ZMB9032 Installation Instructions Manual

Built-in steam oven
Hide thumbs Also See for ZMB9032:
Table of Contents

Advertisement

Available languages

Available languages

4 ELECTRICAL REQUIREMENTS
(Cont.)
This appliance must be supplied with the proper voltage
and frequency and connected to an individual, properly
grounded branch circuit, protected by a circuit breaker or
fuse. See the rating plate located on the underside of the
control panel to determine the rating of the product.
Rating Plate
Location
Rating plate is located on the underside
of the control panel
Use the chart below to determine the minimum
recommended dedicated circuit protection:
KW Rating
240V
4.9 KW–7.2 KW
4.2 KW–6.2 KW
7.3 KW–9.6 KW
6.3 KW–8.3 KW
9.7 KW–12.0 KW
8.4 KW–10.4 KW
DO NOT shorten the flexible conduit. The conduit strain
relief clamp must be securely attached to the junction
box and the flexible conduit must be securely attached
to the clamp. If the flexible conduit will not fit within the
clamp, do not install the oven until a clamp of the proper
size is obtained.
The 3 power leads supplied with this appliance are
suitable for connection to heavier gauge household
wiring. The insulation of these 3 leads is rated for
temperatures much higher than the temperature rating
of the household wiring. The current-carrying capacity
of the conductor is governed by the wire gauge and the
temperature rating of the insulation around the wire.
10
Installation Instructions
Recommended
KW Rating
Circuit Size
208V
(Dedicated)
20 Amp
30 Amp
40 Amp
50 Amp
5 MAKE ELECTRICAL
CONNECTIONS
WARNING
Switch power off at the service panel
and lock the service disconnecting means to prevent
power from being switched on accidentally. When
the service disconnecting means cannot be locked,
securely fasten a prominent warning device, such as
a tag, to the service panel.
Place oven on table or platform even with the cutout
opening. For a steam oven, the platform must
support 170 lbs. (78 kg). Connect the flexible conduit
to the electrical junction box as shown below*.
Position the conduit in such a manner that it will lie
behind the unit in a natural loop when the oven is
installed. You will need to purchase an appropriate
strain relief clamp to complete the connection of the
conduit to the junction box.
Conduit
Place Oven on a
Support to Assist in
Connecting Conduit
* Ovens come equipped with a 40" or 54" long conduit.
If a longer conduit is desired, there may be one
available for your model. To check availability or
order parts, visit monogram.com.
Junction Box
Ground
Wire
Ground
Red
White
Black
Strain Relief Clamp
(not included) Must Be
Used at Junction Box
31-2000693 Rev. 0

Advertisement

Table of Contents
loading

This manual is also suitable for:

Zmb9031

Table of Contents