5-2
SERVICE
REPLACING EVAPORATION FAN
MOTORS AND BLADES
For access to these fans:
1. Remove product and place in a refrigerated
area. Turn off power to the merchandiser.
2. Make sure there is no voltage in the
refrigerator.
3. Remove front grille to acess the machine
compartment.
4. Remove condensing unit screws (Fig. A).
5. Sliding out the condensing unit (Fig. B).
Be careful using the condesing unit plate to
pull out the condensing unit. Make sure do
not stress other parts.
6. Disconnect condenser motor harness.
7. Remove hexagonal screw 5/16" (Fig. C) to
remove squared fan guard.
8. Release screws to remove evaporation fan
assembly (Fig. D).
9. Release motor screws to get motor / blade
assyembly (Fig. E).
10. Change the failed part.
11. If the only damaged part is the motor,
remove blade.
12. Reverse the process and make sure
everything is in place.
Product will be degraded and may spoil if
allowed to sit in a non-refrigerated area.
P/N 3104942_B
U.S. & Canada 1-800-922-1919 • Mexico 01 800-890-2900 • www.hussmann.com