The outdoor unit installation
The outdoor unit installation
Connecting the cable to Outdoor Unit
• Remove the side panel for wiring connection.
• Use the cord clamp to fix the cord.
• Earthing work
- Case 1 :Terminal block of Outdoor Unit have
• Connect the cable of diameter 1.6mm
the control box and do earthing.
- Case 2 :Terminal block of Outdoor Unit don't have
• Connect the cable of diameter 1.6mm
as
and fasten with earth screw.
Please check !!
CAUTION:
• The circuit diagram is not subject to change without notice.
• Be sure to connect wires according to the wiring diagram.
• Connect the wires firmly, so that not to be pulled out easily.
• Connect the wires according to color codes by referring the wiring diagram.
14 Air Conditioner
2
or more to the earthing terminal provided in
2
or more, to the panel of control box, marked
* Make sure the rubber bushes are
Properly used in knock-out holes after
connecting main Power cable
mark.
mark.
Connecting cable terminal
Power cord terminal
Cord clamp
Cord clamp