Optional Operation
Installer Setting-Dry Contact Mode Setting
This function allows the Dry contact-indoor unit operate under Auto Run mode or Manual mode with
remote controller.
* Please refer to dry contact manual for more details.
28 Air Conditioner
1
Press
button for 4 seconds
to enter the installer setting
mode until timer segment
display "01:01".
2
Repeat pressing button to select
Function code 09.
Function Code
Ex) Setting Dry Contact Mode 'ON'
3
Select Dry contact setting by
pressing button.
(00: OFF, 01: ON)
4
Press
button to save or release.
5
Press
button to exit or
system will automatically exit
after 25 seconds without any
input.
Dry Contact setting value