LG UU21WH Installation Manual page 25

Type: high cop inverter
Hide thumbs Also See for UU21WH:
Table of Contents

Advertisement

Installer Setting -Thermistor
❊ Therefore system will use value that sensed from indoor unit or remote controller
<Thermistor Table>
Temperature sensor location
01 Indoor unit
02 Remote controller
03 2-Thermistor(2TH)
1
Press
to enter the installer setting
mode until timer segment
display "01:01".
2
Repeat pressing
Function code 04.
Ex) Setting Thermistor as '2TH'.
3
Set Thermistor mode by pressing
button. (01: Remote Controller,
02: Indoor, 03: 2TH)
4
Press
5
Press
system will automatically exit
after 25 seconds without any
input.
Operation in indoor unit temperature sensor
Operation in remote controller Temperature sensor
Operation in lower temperature after comparing the temperature
between the indoor unit and remote controller
Optional Operation
button for 4 seconds
button to select
Function Code
Thermistor setting
button to save or release.
button to exit or
Function
Installation Manual 25

Advertisement

Table of Contents
loading

This manual is also suitable for:

Uu24wh

Table of Contents