IP Input Configurations
Important:
If the IP input uses MPTS streams, then each stream can
contain one or more services. An MPTS stream may use the
same PID (Package ID) for two or more of the services that it
contains.
However, the headend system cannot output services with the
same PID. To discover services with the same PID is NOT
possible until you have selected the services with identical PIDs
in order to output them using an output module or a Link socket.
If you attempt to output services with identical PIDs:
 the System Status LED turns red on the unit that tries to
output the IP services,
 the System icon of the affected headend unit turns red on
the System tab in the Service Tool,
 the System Status LED and System icon turn red on the
main unit in a multi-unit installation.
See "Duplicated PIDs" for further information.
7. View the Status information area to ensure that IP data is
being sourced through the Link socket.
8. Press the Submit button.
The selected service is now available in the headend service pool.
9. Press the Apply button to save the new settings in the
configuration.