242
Display
ALARM (71)
Ex. Device Bay2 +5.0V low.
ALARM (72)
Ex. Device Bay2 +5.0V high.
ALARM (73)
Ex. Device Bay2 +12.0V low.
ALARM (74)
Ex. Device Bay2 +12.0V high.
ALARM (75)
Ex. Device Bay2 FAN1 RPM slow.
ALARM (76)
Ex. Device Bay2 AC lost.
ALARM (77)
Ex. Device Bay2 power sag.
ALARM (78)
Ex. Device Bay2 power supply fault.
ALARM (79)
Ex. Device Bay2 temp high.
ALARM (80)
Ex. Device Bay2 fuse blow out.
ALARM (87)
Internal HDD error.
ALARM (88)
Memory error in BIOS POST. Resized.
ALARM (89)
Correctable memory ECC error.
ALARM (90)
Uncorrectable memory ECC error.
ALARM (91)
Critical interrupt (NMI) occurred.
ALARM (92)
Critical interrupt (SMI) occurred.
ALARM (93)
Critical interrupt (PERR) occurred.
ALARM (94)
Critical interrupt (SERR) occurred.
ALARM (95)
No boot device.
Meaning of Message
Low voltage error of External Device Bay Unit 2+5.0V power
supply.
High voltage error of External Device Bay Unit 2+5.0V power
supply.
Low voltage error of External Device Bay Unit 2+12.0V power
supply.
High voltage error of External Device Bay Unit 2+12.0V power
supply.
The External Device Bay Unit 2 fan 1 slow rpm error has
occurred.
Power interruption reset was detected on External Device Bay
Unit 2.
Momentary power interruption was detected on External Device
Bay Unit 2.
The External Device Bay Unit 2 fuse has blown.
The External Device Bay 2 high temperature error has occurred.
The External Device Bay 2 fuse has blown.
An internal HDD error has occurred.
Memory error has occurred. Memory has been reduced.
Correctable error has occurred.
Uncorrectable error has occurred.
Fatal error (SMI) has occurred.
Fatal error (NMI) has occurred.
Fatal error (PERR) has occurred.
Fatal error (SERR) has occurred.
Cannot find boot device.