7 3 External Sync

When using the unit with an external sync signal to EXT. SYNC terminal on the rear panel.
When the external sync signal is input, the camera automatically switches its sync from the internal sync to
the external sync.
EXT. SYNC input
SYNC

1 External sync signal input conditions

SYNC 75
unbalanced

2 External sync frequency range

(59.94 Hz Setting)
(60 Hz Setting)

3 Using the unit with external sync signal

Adjust H (Horizontal) phase if necessary to match the output of multiple cameras.
When adjusting H (Horizontal) phase, refer to the item "7.2 (6) SYNC".
3. 1 H (Horizontal) phase adjustment
Observe the external sync signal and the video signal output
waveform of the unit with a dual trace oscilloscope, and adjust
H phase so that the H phases match.

7 4 Synchro. Scan Operation

The shutter speed can be set by the horizontal scanning period (1H).

1 Setting by 1H

1/1125H to 560/1125H stands for the setting by the 1H and the shutter speed can be set by the 1H.
0.6 V (p-p) standard
H : 33.716 Hz
35 ppm
V : 59.94 Hz
35 ppm
H : 33.75 Hz
35 ppm
V : 60 Hz
35 ppm
Operation
External sync with SYNC
Match
the phase.
31
External
Sync. signal
Camera
Sync. output