Factory Patten Detection - Midea RW145 Service Manual

Table of Contents

Advertisement

2 FACTORY PATTEN DETECTION

2. Service mode
L1
L2
L3
L4
L5
L6
2.1 Versions information checking
Rotate the nob to any program from "ON/OFF", Press
the"L1","L3",L1","L3"button in order in 10 seconds, then the door will be
locked(L5 turns on), L4 turns on. that means machine enters service testing mode.
Testing 01 ,and the abbreviation is T01. (note: All the lights in the bottom line show in
binary format. The L4 light means number 1, so as the T01. L3 light means number 2,
L2 means number 4, and L1 means number 8.) press L4 , L6 will turn on, and the lights
in bottom line show the project version; in binary format.
2.2 Display the error code mode
After entering service testing mode, press L1,until L3,L5 turn on. The others turn off.
That means T02,error mode.
1) Press L4 two times. Then the four lights in the bottom line shows the error code. if
L1 twinkles only, that means no error. You can check the others error codes ,according
to the Schedule of failure alarm
the machine runs The "K1" light display the error code is index(the index with1-10).
2) Press the "L1" changed into the error code with last time, there is display 10
times at most.
4) It can memory 10 error codes at most, the two error connection only record one time
5) Clear all the error codes : press L2+L3 3seconds, all error codes after hearing buzzing.
6) Press L4 again, and you will exit error mode.
Prewash
Extra Rinse
No Spin
Pause Start
Door Lock
Child Lock
6

Advertisement

Table of Contents
loading

Table of Contents