C-3
9. Gently slide the barrel up to the torch head.
Continue sliding the barrel carefully over the o-rings
of the torch head, until the hole of the torch head
adapter aligns with the threaded hole of the torch
head. Fasten together using the flat head screw with
5/64" allen wrench, until the head of the screw is
fully seated in the countersunk hole.
10. Thread strain relief nut into barrel and tighten
(Recommended torque - 70-80 in-lbs.). Thread
strain relief onto strain relief nut and tighten
(Recommended torque - 50-60 in-lbs.).
Strain Relief
Strain Relief Nut
11. Minimum safety check: using an ohm meter verify
that greater than 10 megohms exists between the
barrel and all of the pins on the central adapter
assembly.
12. Restore power to the machine.