FFD Inspection and adjustment
Preparation
・ Turn the objective glass of the collimator (J19019), and set
degree to 0 (0 mm).
・ Set the 0-position of " Adjusting focus stand for APS (J15327)" as follows:
1. Replace the white acrylic plate of the above stand(J15327)with the new one(J15327A)
2. Install J15327D to the micro stand.
3. Align the upper surface of the white acrylic plate of the Adjusting focus stand (J15327A) with the mirror
reflecting surface.
Note: Because the mirror reflecting surface is easily damaged, carefully align with it at the same
level by using the dial gauge, etc.
4. Based on the above 0-position, turn the knob of the Adjuting focus stand further to set the -2.16-mm position.
5. Press the reset button of the Adjusting focus stand again, and set the 0-position.
FFD inspection and adjustment
(*FFD:Flange Focal Distance)
Collimator
Lens-barrel unit
At the position where the color of vertical lines shifts from blue to
red, read the measurement value of the Adjusting focus stand.
- A8・ E5600 -
VAA31001-R.3651.A
Zoom position
FFD standard
Wide-side
± 0.05mm
Tele-side
± 0.05mm
Adjusting focus stand for APS (J15327)