TROUBLESHOOTING
B. Misfeed in the fusing area
1
Gently pull on the top center of the
front cover to open.
2
Turn the roller rotating knob in the
direction of the arrow.
Roller rotating knob
3
Carefully remove the misfed paper.
Lower the fusing unit release levers to
allow easier removal.
Fusing unit
release lever
The fusing unit is hot. Do not touch
the fusing unit when removing
misfed paper. Doing so may cause a
burn or injury.
• Do not touch the photoconductive drum
(green portion) when removing the misfed
paper. Doing so may damage the drum
and cause smudges on copies.
• Be careful about unfixed toner on the
misfed paper not to soil your hands or
clothes.
50
Be careful not to tear the
misfed paper during
removal.
4
Lift the fusing unit release levers, to
return them to their operating
positions.
5
Close the front cover and side cover.
• When closing the front cover, gently hold
Note
both ends.
• When closing the side cover, press on the
handle.
• If the misfeed indicator (
stop blinking, check for torn pieces of
paper in the machine.
The misfeed indicator
(
) will go out.
) does not