Caution
In systems with several heat pumps, each
pump is allocated a unique ID. In other words,
only one heat pump can be "master" and only
one can be "slave 5".
MENU 5.2.2 - INSTALLED SLAVES
Set which slaves are connected to the master heat
pump.
There are two ways of activating connected slaves. You
can either mark the alternative in the list or use the
automatic function "search installed slaves".
NOTE
Before these settings are made, each slave
must have received a unique ID (see menu
5.2.1).
MENU 5.2.3 - DOCKING
Enter how your system is docked regarding pipes, for
example to pool heating, hot water heating and heating
the building.
This menu has a docking memory which means that the
control system remembers how a particular reversing
valve is docked and automatically enters the correct
docking the next time you use the same reversing valve.
Master/slave
master
s1
s2 s3 s4 s5 s6 s7 s8
F1255
Compressor
Master/slave: Select the heat pump for which the
docking setting is to be made (if there is only one heat
pump in the system, only master is displayed).
Compressor: Here, you select whether the compressor
is blocked, externally controlled via soft input or standard
(docked for example to pool heating, hot water charging
and heating the building).
Marking frame: Move around the marking frame using
the control knob. Use the OK button to select what you
want to change and to confirm the setting in the options
box that appears to the right.
50
Chapter 8 | Control - Menus
Workspace for docking
docking5.2.3
Marking frame
Workspace for docking: The system docking is drawn
here.
Symbol
Description
Compressor (blocked)
Compressor (externally controlled)
Compressor (standard)
Reversing valves for hot water, cooling re-
spectively pool control.
The designations above the reversing valve
indicate where it is electrically connected
(EB100 = Master, EB101 = Slave 1, CL11
= Pool 1 etc.).
Own hot water charging, only from selected
heat pump compressor. Controlled by relev-
ant heat pump.
Pool 1
Heating (heating the building, includes any
extra climate system)
Cooling
MENU 5.2.4 - ACCESSORIES
Inform the heat pump which accessories are installed
here.
There are two ways of activating connected accessories.
You can either mark the alternative in the list or use the
automatic function "search installed acc.".
search installed acc.
Mark "search installed acc." and press the OK button to
automatically find connected accessories for F1255.
Caution
Certain accessories are not found with the
search function, but must be selected instead
in menu 5.4.
NOTE
Only mark the option for ground water pump
if the accessory AXC 40 is to be used to control
the circulation pump.
MENU 5.3 - ACCESSORY SETTINGS
The operating settings for accessories that are installed
and activated are made in the sub-menus for this.