Nibe F1255 Installation Manual page 48

Ground source heat pump
Hide thumbs Also See for F1255:
Table of Contents

Advertisement

For manual operation of the brine pump, deactivate
"auto" and set the value to between 1 and 100 %.
For operation of brine pump with "fixed delta", select
"fixed delta" under "op. mode" and set the value between
2 and 10 °C.
If there are accessories for cooling, you can also set the
brine pump's speed during passive cooling operation
here (the brine pump then runs in manual operation).
If the continuous operating mode (see
operating mode brine pump", page
ted one can also choose waiting mode. The circulation
pump continues to run while the compressor stops.
This menu is also set in the slave heat pump's limited
menu system.
MENU 5.1.10 - OP. MOD HEAT MED PUMP
op. mode
Setting range: auto, intermittent
Default value: auto
Set the operating mode of the heating medium pump
here.
auto: The heating medium pump runs according to the
current operating mode for F1255.
intermittent: The heating medium pump starts approx.
20 seconds before, and stops at the same time as, the
compressor.
MENU 5.1.11 - PUMP SPEED HEATING
MEDIUM
Operating status
Setting range: auto / manual
Default value: auto
Manual setting, hot water
Setting range: 1 - 100 %
Factory setting: 70 %
Manual setting, heating
Setting range: 1 - 100 %
Default values: 70 %
Manual setting, pool
Setting range: 1 - 100 %
Default values: 70 %
48
Chapter 8 | Control - Menus
speed in wait mode
Setting range: 1 - 100 %
Default values: 30 %
min. allowed speed
Setting range: 1 - 50%
Default values: 1 %
"Menu 5.1.8 -
max. allowed speed
47) has been selec-
Setting range: 50 - 100 %
Default values: 100 %
speed active cooling (accessory is required)
Setting range: 1 - 100 %
Default values: 70 %
speed passive cooling (accessory is required)
Setting range: 1 - 100 %
Default values: 70 %
Set the speed at which the heating medium pump is to
operate in the present operating mode. Select "auto" if
the speed of the heating medium pump is to be regu-
lated automatically (factory setting) for optimal operation.
If "auto" is activated for heating operation you can also
make the setting "max. allowed speed" which restricts
the heating medium pump and does not allow it to run
at a higher speed than the set value.
For manual operation of the heating medium pump,
deactivate "auto" for the current operating mode and set
the value to between 0 and 100% (the previously set
value for "max. allowed speed" no longer applies).
"heating" means heating operating mode for the heating
medium pump.
"speed in wait mode" means heating or cooling operating
mode for the heating medium pump, but when the heat
pump requires neither compressor operation nor electric
additional heat and slows down.
"hot water" means hot water operating mode for the
heating medium pump.
"pool" (accessory required) means pool heating operating
mode for the heating medium pump.
"cooling" (accessory required) means operating mode
cooling for the heating medium pump.
If there are accessories for cooling present or if the heat
pump has a built-in function for cooling you can also set
the heating medium pump speed during active respect-
ively cooling operating modes (the heating medium
pump then runs in manual operation).
NIBE F1255

Hide quick links:

Advertisement

Table of Contents
loading