13.7.3 Fundamental Parameters #1

Parameter
Function / Title
MAXIMUM OUTPUT
0026
FREQUENCY
BASE FREQUENCY #1
0027
BASE FREQUENCY
0028
VOLTAGE SELECT
MAXIMUM OUTPUT
0029
VOLTAGE #1
REVERSE OPERATION
002A
DISABLE SELECT
UPPER LIMIT FREQUENCY
002B
LOWER LIMIT FREQUENCY
002C
VOLTS PER HERTZ
002D
PATTERN
VOLTAGE BOOST
002E
1, 2
#1
ACCELERATION TIME #1
002F
DECELERATION TIME #1
0030
ACC/DEC PATTERN #1
0031
SELECTION
ACCEL/DECEL PATTERN
0032
ADJUST LOW
ACCEL/DECEL PATTERN
0033
ADJUST HIGH
Note 1:
Parameter data = (desired setting x 5 + 3), converted to hexadecimal
Bank
Mask
0 / 1
FFFF
(*)
0 / 1
FFFF
0 / 1
0030
(*)
0 / 1
FFFF
0 / 1
0020
0 / 1
FFFF
0 / 1
FFFF
0 / 1
000F
(*)
0 / 1
FFFF
0 / 1
FFFF
0 / 1
FFFF
0 / 1
0030
0 / 1
00FF
0 / 1
00FF
69
Adjustment Range
0BB8 ∼ 9C40 (30.00∼400.00)
09C4 ∼ 9C40 (25.00∼400.00)
0000: Input voltage level
0020: Automatic setting
0030: Stationary setting
0000 ∼ 0258 (0 ∼ 600)
0000: Reverse allowed
0020: Reverse not allowed
0000 ~ Fmax
0000 ∼ UL, Fmax
0000: Constant torque
0001: Variable torque
0002: Auto. torque boost
0006: #3 w/ auto. energy savings (4)
000A: Vector control
000E: #5 w/ auto. energy savings (6)
0000 ∼ 012C (0.0 ∼ 30.0)
0001 ∼ EA60 (0.01~ 600.00)
0001 ∼ EA60 (0.1~ 6000.0)
0001 ∼ EA60 (0.01~ 600.00)
0001 ∼ EA60 (0.1~ 6000.0)
0000: Linear
0010: Self-adjusting
0020: S-Pattern #1
0030: S-Pattern #2
0003 ~ 00FD (0 ∼ 50) (Note 1)
0003 ~ 00FD (0 ∼ 50) (Note 1)
Multiplier
0.01
0.01
(0)
(1)
(2)
1
(0)
(1)
0.01
0.01
(1)
(2)
(3)
(5)
0.1
0.01
0.1
0.01
0.1
(0)
(1)
(2)
(3)
1
1