Needle plate switch (method 1)
1
2
Needle plate
attached:
Needle plate for
straight stitch
attached:
Needle plate replacing bar
Mechanical adjustment
S symbol blinks
S symbol appears
3 appears
32
To check:
1. While pressing the needle up/down and aut-lock stitch
buttons, turn the power switch on.
The LCD display "----".
Press "5" key to enter the sensor test mode.
2. Be sure that S symbol appears and blinks when the
needle plate is attached.
3. Replace the needle plate with the needle plate for
straight stitch. Be sure that S symbol and number 3
appears.
If not, adjust the micro switch base plate position (see
page 28).
* To remove the needle plate, press the needle plate
replacing bar in the direction of arrow with a
screwdriver.