Fak - Length Scaling Factor - Rexroth Indramat CLM1.4 Manual

2 (4) axis positioning control with profibus
Table of Contents

Advertisement

5-28
Writing the User Program
FAK – Length Scaling Factor
FAK V600 V601
FAK 1 1.234567
or
Multiplication factor
Input: from 0.000000 to 1.999999
Axis: 1 to 4
Positioning travel of the 'POA,' 'POI,' 'PSI' and 'PSA' commands is always
the result of a preselected linear value or position and a multiplication
factor.
The formula below applies for incremental positioning:
Positionin
g
Travel
Fig. 5-11: Calculation of Incremental Positioning
The formula below applies for absolute positioning:
Target
Position
=
Preset
Fig. 5-12: Calculation of Absolute Positioning
Each change in the factor applies to all subsequent positioning motions. A
positioning motion already in progress is no longer affected by changes in
this factor.
To make a change in the operating mode (Manual/Automatic), the
multiplication factor is preset to a value of 1.000000.
0000
PSI
1 +000100.000 999
0001
JSR
0100
0002
FAK
1 1.234500
0003
PSI
1 +000100.000 999
0004
JSR
0100
0005
FAK
1 1.000300
0006
PSI
1 +000100.000 999
Fig. 5-13: Example of Multiplication Factor for Positioning Motions
The program proceeds to the next instruction following the time period of
one cycle.
×
=
Preset
Length
Multiplica
×
Absolute
Position
Multiplica
- Positioning = 100
- Positioning = 123.45
- Positioning = 100.03
DOK-CONTRL-CLM01.4LAP1-FK01-EN-P
CLM01.4-LAP-01VRS
tion
Factor
tion
Factor

Advertisement

Table of Contents
loading

Table of Contents