46/143
Bosch Rexroth AG
Transport and Storage
LSA Control S.L. www.lsa-control.com comercial@lsa-control.com (+34) 960 62 43 01
Rexroth Sytronix FcP 50xx/70xx Motor-Pump Unit MPES2
A10VZO/A4VSO
Bearing time / months
Measures for storage
< 12
< 24
> 24
Coat the inner side of the axial piston unit with mineral oil by filling
●
in approx. 100 ml mineral oil.
Fill in anticorrosion agents VCI 329 (20 ml) into the axial piston
●
●
unit.
1. Filling must be done via the tank connection L or L1, refer to
Rexroth Sytronix, Assembly and Commissioning, Axial Piston
Variable Pump A10VZO/A10VSO/A4VSO, material number:
R911341628.
2. Hermetically seal all connections.
3. Coat all unpainted surfaces of the axial piston pump with miner‐
al oil.
4. or suitable, easy to remove anticorrosion agents, e.g. acid-free
grease.
5. Hermetically pack the axial piston pump and a drying agent into
anticorrosion foil.
6. Store the axial piston pump shockproof.
Measures for commissioning
Before mounting, check the complete axial piston pump for dam‐
●
●
●
age and corrosion.
At a test run, check the axial piston pump for functionality and
●
●
●
leakproofness.
●
Change the shaft sealing ring.
After the maximum storage time (24 months) we recommend a
●
preventive check of the axial piston pump by the responsible
Rexroth service!
Tab. 6-10:
Measures for storage and before commissioning axial piston pumps
that have been stored over a prolonged period of time
DOK-SYTROX-MPES2******-IT01-EN-P
Need help?
Do you have a question about the Rexroth Sytronix FcP 50 Series and is the answer not in the manual?