OPERATING Charging ..............................Wearing ................................ Power on ..............................Power off ..............................Connectivity light ............................ Viewing G7’s assigned user ........................ GAS DETECTION Bump test ..............................Calibration ..............................Bump test and calibration reminder window................Bump test and calibration lock ......................Zero sensors ..............................
Page 3
CARTRIDGES Gas Cartridge replacement program .................... Changing cartridges ..........................Cartridge care ............................Cartridge safety precautions ......................Multi-gas pump cartridge ........................Using pump ............................. Pump options ..........................REAL-TIME FEATURES Yellow pending alarm features ......................Potential Fall detected ....................... Potential no-motion detected ....................Check-in request ...........................
Blackline Live™ web portal application, your monitoring account and your G7. G7 devices require an active service plan in order to connect to the Blackline Safety Network. Depending on your needs and requirements, various service plan options are available such as 24/7 safety monitoring by Blackline’s Safety Operations Center and...
BLACKLINE LIVE WEB PORTAL What is Blackline Live? G7 utilizes the cloud-hosted Blackline Live web portal to monitor and manage all your workers and devices, as well as deliver reports and business analytics insights. With Blackline Live’s real-time alerting and live map with employee locations, you can quickly locate and respond to a worker in distress.
There are two G7 models: G7c and G7x. The main difference between them is how they connect to the Blackline Safety Network. If you are unsure of which G7 model you have, refer to the logo on the front of your G7. G7c works anywhere with 2G/3G G7x works in conjunction with Blackline’s...
DEVICE COMPARISON What features does my G7 have? G7c and G7x are customized with one of four cartridge types. Cartridge selections include Standard, Single-gas, Multi-gas diffusion and Multi-gas pump cartridges. The following comparison chart summarizes the features of each cartridge.
WHAT’S IN THE BOX Your G7 device comes with the following components: G7 personal safety monitoring device Pre-installed cartridge (Standard, Single-gas or Multi-gas cartridge) Getting started guide Optional real-time features guide Charging system • Removable charging clip •...
Single-gas or Multi-gas) light Speaker LCD screen Up button Down button OK button Latch pull Power button Latch push button Microphone (G7c only) Charging light Cartridge label Metal belt clip Product label Charging port G7 TECHNICAL USER MANUAL || 9...
INTERACTION HOW IT WORKS Interacting with G7 is easy with its high-visibility LCD display and three-button menu system. OK button Up and down arrow buttons Press OK to enter the main menu on Press up or down to navigate the menu.
Insert the micro USB plug into the removable charging clip, then slide the clip onto the charging port at the bottom of your G7. A solid red light at the bottom of the device confirms your G7 is charging. The LCD screen will let you know when it is fully charged, which can take up to four hours.
How do I turn on my G7x? Press and hold the power button on your G7 Bridge to turn it on first, and wait for the blinking green connectivity light to turn solid, it takes approximately two minutes for G7 Bridge to connect to the Blackline Safety Network.
G7 lets you know your connection status. Blinking/Solid Blinking green light A blinking connectivity light indicates that your G7 is storing data. It is not currently connected to the network and will send data when the light is solid. Solid green light A solid connectivity light indicates that G7 is actively transmitting data and is connected to the Blackline Safety Network.
G7 can be assigned a team member in Blackline Live. From Blackline Live, there is also the option to display the assigned user on the device, which allows you to identify which device belongs to which user. G7 does not have to be assigned a user to function as a safety monitor or gas detector.
BUMP TEST What is a bump test? It is safe practice to regularly test gas sensors by applying the target gas. G7’s bump test also tests the operation of light, sound and vibration indicators. The bump test schedule depends on your company’s safety policy. G7 automatically communicates bump test data to the Blackline Safety Network, and will remind you when a bump test is overdue.
Page 16
Tubing Single-gas calibration cap Tubing Multi-gas calibration cap 16 || G7 TECHNICAL USER MANUAL...
You can individually choose which sensors to test. By default, G7 will test all sensors. Attach the calibration cap to your device G7 will begin to count down from 60. Apply the gas within this time window and continue to apply gas for 2 minutes.
If a bump test or calibration comes due during your shift (not on startup), the device will not lock as this is a safety hazard, since the user will not be able to use G7 to call for help. The device will go into a yellow warning alarm for bump test or calibration due, and the message will display in the banner, but the device will remain fully functional.
ZERO SENSORS What is zeroing? If G7 is not reading zero and you know you are in an atmosphere with no gas, your gas sensor readings may have shifted. If this happens, it is best to calibrate your sensors. If you are unable to preform a calibration, you can zero your sensors to reset the baseline.
GAS DETECTION FEATURES Once you have completed a bump test and calibration, G7 is ready to monitor and notify you of gas exposure. Gas detection alarms will notify you with either a yellow warning alarm or a red alert depending on the gas level measured. All settings are customizable in Blackline Live.
BUMP TEST When does G7 trigger a bump test yellow warning alarm? When gas sensors are due for a bump test, G7 will inform you with a yellow warning alarm. PUMP BLOCK When does G7 trigger a pump block yellow warning alarm? If your pump inlet is blocked, G7 will inform you with a yellow warning alarm.
RED ALERT GAS FEATURES Rapid Blinking HIGH ALERT FOR GAS When does G7 trigger a high alert for gas? If a gas sensor detects gas levels above the high gas concentration threshold configured by your safety supervisor. A G7 with O...
If a toxic sensor detects you have exceeded the average allowable amount of gas during an eight-hour period. The two TWA measuring methods available for use on your G7 are: NOTE: OSHA (United States Department of Labor Occupational Safety and Health Administration) or ACGIH (American Conference of Governmental Industrial Hygienists).
Configuration modes are customized in the G7 configuration profile on Blackline Live. Each profile supports up to a total of five ‘modes’ . These modes allow G7 to temporarily change its behavior for different situations, and can be turned on and off through G7’s interface.
If you select yes, your mode will be extended. If you select no, G7 will return to normal operation. If you do not make a selection within 30 seconds, G7 will automatically return to normal operation. If you have a check-in timer enabled, G7 will immediately ask you to check in.
What do I do when I need a new gas cartridge? If you have an uninterrupted service plan for your G7 gas cartridge, Blackline will replace expired cartridges for you free of charge. To inquire about or request new cartridges, please contact our Customer Care team or your distributor.
Blackline’s NDIR sensor does not detect Hydrogen or Acetylene. Like any gas sensor, please be sure you understand your potential explosive hazards and choose the appropriate sensor technology based on these hazards. Blackline’s LEL-MPS sensor does not require calibration. G7 TECHNICAL USER MANUAL || 27...
When a pump cartridge is attached to G7, you can see the pump status screen by pressing the up or down arrow from G7’s main screen. Here you can see if pump is on or off, your hose length, flow rate and sample time (if enabled).
150 ml/min. A flow rate less than 150 ml/min will result in a pump block yellow warning alarm. By default, Blackline’s pump aims to maintain a flow rate of 300ml/min and G7 will automatically adjust its pump speed to maintain this rate.
REAL-TIME FEATURES Your G7 can be equipped with many features to monitor your safety. They are categorized into the type of notifications they trigger — yellow pending alarms, yellow warning alarms, and red alerts. All are customizable in Blackline Live to best fit your needs. Speak to your safety supervisor to learn about how your G7 features are configured.
The check-in countdown is displayed at the top right of the LCD screen. At the end of the timer, your G7 will initiate a yellow pending alarm to confirm you are safe. The check-in timer and pending alarm time are configurable.
How do I receive a message? Your device can receive messages from monitoring personnel. When there is an incoming message, G7 will inform you with a yellow warning alarm. How do I send a message? You can choose from a list of 10 pre-programmed messages to send to monitoring personnel.
How do I use two-way voice calling? If you have a G7c with a voice-enabled service plan, your speakerphone will automatically answer a call from monitoring personnel. G7 will inform you of an incoming call with a yellow warning alarm and you will hear a beep signifying the two-way voice call has been connected.
FALL DETECTED What is fall detected? If your device detects a fall and you have not responded to the yellow pending alarm, G7 will communicate a red alert to monitoring personnel. The fall detection sensitivity is configurable. NO-MOTION DETECTED What is no-motion detected? If you are not moving and you have not responded to the yellow pending alarm, G7 will communicate a red alert to monitoring personnel.
What do I do in the case of a red alert? Red alerts are immediately communicated to monitoring personnel. Read the information on your G7 screen. Press and hold the up and down arrow buttons at the same time to mute the sound and vibration.
In the case that a silent SOS alert is sent, the blue LiveResponse light will not shine. Instead, G7 can be configured to vibrate to let you know that remote monitoring personnel are responding by following your team’s emergency protocol.
When G7c finishes beeping, continue to hold and begin talking with the device about 6 inches from your mouth. If you are using an O2 sensor, be sure that you are talking into G7’s NOTE: microphone, not the cartridge, as this could cause gas alarms.
CHANGING VOLUME How do I change my push-to-talk call volume? Changing the volume of incoming calls can be done from G7’s main screen or the PTT channel menu. Changing your PTT volume only affects incoming calls, and won’t change the way G7’s alerts sound.
Put your audio accessory into pairing mode as per its instructions Select your audio accessory from the list G7 will give you a successful connection message when your device is connected, and you will see an audio accessory icon in the info bar of G7c’s main screen...
Blackline Safety will contact you directly for specific information about new updates. If you have any questions, please contact our Customer Care team. OTA firmware updates are only available for G7 Bridge when it is brought into NOTE: cellular range. If G7 Bridge cannot be removed from satellite only reception, contact Customer Care to receive a firmware update kit.
SUPPORT LEARN MORE Visit support.BlacklineSafety.com to find support and training materials for G7. CUSTOMER CARE For technical support, please contact our Customer Care team. North America (24 hours) Toll Free: 1-877-869-7212 | support@blacklinesafety.com United Kingdom (8am-5pm GMT) +44 1787 222684 | eusupport@blacklinesafety.com...
Low gas alert Antenna: Internal regionally optimised Bump test and calibration notification G7x wireless radio Bump test and calibration failure Works with G7 bridge satellite base station Size & weight Radio: 902.0–928.0 MHz, 1 Watt G7 with Standard Cartridge Antenna: Internal Size: 64 mm x 124 mm x 27 mm (2.52”...
Page 43
0.01 ppm Photoionisation (PID) 0–6,000 ppm 0.1 ppm (0–100 ppm), 2 ppm (100–6,000 ppm) Sulphur dioxide (SO2) Electrochemical 0–100 ppm 0.1 ppm * Check with Blackline for approval status. All specifications subject to change. G7 TECHNICAL USER MANUAL || 43...
Warranty Your G7 device is warranted against defects in materials and workmanship for up to two years from date of purchase. For further details regarding your Blackline warranty, please refer to your terms and conditions of service. FCC Compliance This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC rules.
II 1 G -20°C <= Ta <= +55°C Base unit P/N “G7*-#” (* = c, x, or blank; # = NA, EU or AZ) Gas cartridge: Standard P/N “Z” | Single-gas P/N “S-#” | Multi-gas P/N “Q-####” | Pump Module P/N “P-####” (# = Electro chemical sensor identifier or “X” indicating no sensor) Caution: For safety reasons this Attention: Pour des raisons de sécurité,...