Amplifier Access - Infinity Beta SW Series Service Manual

Hide thumbs Also See for Beta SW Series:
Table of Contents

Advertisement

CSW-10
Parameter
Specification
Signal Sensing (ATO)
Auto-Turn-On (yes/no)
ATO Input test frequency
ATO Level LFE Input
ATO Level Speaker in
ATO Turn-on time
Auto Mute/ Turn-OFF Time
Power on Delay time
Transients/Pops
ATO Transient
Turn-on Transient
Turn-off Transient
Efficiency
Efficiency
Stand-by Input Power
Stand-by Input Power
Power Cons. @ 400W
Protection
Short Circuit Protection
Thermal Protection
DC Offset Protection
Line Fuse Rating
USA-Domestic
EU
QA Test
Unit
Limits
functional Auto - on selection switch in Auto
YES
50
Hz
functional
2.5
mV
functional
30
mV
functional
Amp connected and AC on, then
functional
input signal applied
2
seconds
(T) Time before muting, after input
15
minutes
17
signal is removed
2
sec.
4
AC Power Applied
5
mV-peak
n/a
@ Speaker Outputs
50
mV-peak
1V-pk-pk @ Speaker Outputs
50
mV-peak
1V-pk-pk @ Speaker Outputs
68
%
65
400W of output power
@ nominal line voltage, Amp in
18
20
OFF state, RED LED activated
@ nom. line voltage, Amp in On
22
Watts
25
state, Green LED activated
615
584
Watts
@ nom. line voltage
NO
N/A
YES
functional @1/8 max unclipped Power
YES
-
DC present at Speaker Out leads
5
Amps
Type-T or Slo Blo-250 V
2.5
Amps
Type-T or Slo Blo-250 V
Conditions
"
"
"
Auto turn of time (T) must be 10 > T < 17
Minutes
AC Line cycled from OFF to ON
AC Line cycled from ON to OFF
Nominal Line voltage 120 VAC
Maximum allowable input power LED in RED,
Class D inactive
Maximum allowable input power under nominal
Input voltage and frequency, in stand-by mode
(HOT or COLD operation, LED GREEN). Class
D active but no signal applied.
400 Watts into 4 Ohms nominal line voltage
Temperature rise in accessible metal parts
should not exceed 35K rise for domestic version
or 30K rise for European versions (refer to
requirements sheet). Unit is protected for over-
temperature conditions
Relay opens during a DC output condition
Internal fuse with UL/SEMKO rated holder
3
Notes

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Beta csw-10

Table of Contents