Download Print this page
Sealey SAC2276B.V2 Manual

Sealey SAC2276B.V2 Manual

270ltr belt drive 2 x 3.0hp with cast cylinders

Advertisement

Quick Links

Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these instructions
and maintained properly, give you years of trouble free performance.
IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE THE PRODUCT
CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR PERSONAL INJURY AND WILL
INVALIDATE THE WARRANTY. KEEP THESE INSTRUCTIONS SAFE FOR FUTURE USE.
Warning:
Refer to
Electricity
Instructions
1.
SAFETY
1.1.
ELECTRICAL SAFETY
 WARNING! It is the responsibility of the owner and the
operator to read, understand and comply with the following: You
must check all electrical products, before use, to ensure that
they are safe. You must inspect power cables, plugs, sockets
and any other connectors for wear or damage. You must ensure
that the risk of electric shock is minimised by the installation of
appropriate safety devices. A Residual Current Circuit Breaker
(RCCB) should be incorporated in the main distribution board.
We also recommend that a Residual Current Device (RCD) is
used. It is particularly important to use an RCD with portable
products that are plugged into a supply which is not protected by
an RCCB. If in any doubt consult a qualified electrician. You may
obtain a Residual Current Device by contacting your Sealey
stockist. You must also read and understand the following
instructions concerning electrical safety.
1.1.1. The Electricity at Work Act 1989 requires that all portable
electrical appliances, if used on business premises, are tested
by a qualified electrician, using a Portable Appliance Tester
(PAT), at least once a year.
1.1.2. The Health & Safety at Work Act 1974 makes owners of
electrical appliances responsible for the safe condition of those
appliances and the safety of the appliance operators. If in any
doubt about electrical safety, contact a qualified electrician.
1.1.3. Ensure that the insulation on all cables and on the appliance is
safe before connecting it to the power supply. See 1.1.1. and
1.1.2. and use a Portable Appliance Tester.
1.1.4. Ensure that cables are always protected against short circuit
and overload.
1.1.5. Regularly inspect power supply cables and plugs for wear or
damage and check all connections to ensure that none are loose.
1.1.6. Important: Ensure that the voltage marked on the appliance
matches the power supply to be used and that the plug is fitted
with the correct fuse (see 1.1.10. below).
1.1.7. DO NOT pull or carry the appliance by the power cable.
1.1.8. DO NOT pull the plug from the socket by the cable.
1.1.9. DO NOT use worn or damaged cables, plugs or connectors.
Immediately have any faulty item repaired or replaced by a
qualified electrician.
© Jack Sealey Limited
COMPRESSOR - 270LTR BELT DRIVE
2 x 3.0HP with CAST CYLINDERS
MoDEL no:
Warning:
Warning:
Hot Surface
Automatic
Start-up
Original Language Version
SAC2276B.V2
1.Direct Compressed Air outlet
2.Tank
3.on/off Switches
1.1.10. A 32amp supply is required and we recommend that a 32Amp
industrial round pin plug should be fitted and connected to a
32Amp supply having a Type C breaker. If in doubt, you must
contact a qualified electrician to ensure that a suitably rated
supply is available.
IMPORTANT! The use of extension leads to connect these
compressors to the mains is not recommended as the resulting
voltage drop reduces motor, and therefore pump performance.
1.2.
GENERAL SAFETY
Familiarise yourself with the application and limitations of the
3
compressor.
Ensure the compressor is in good order and condition before
3
use. If in any doubt do not use the unit and contact an
electrician/service agent.
WARNING! Compressor must only be serviced by an
authorised agent. DO NOT tamper with, or attempt to adjust,
pressure switch or safety valve.
Before moving, or maintaining the compressor ensure it is
3
unplugged from the mains supply and that the air tank pressure
has been vented.
Maintain the compressor in good condition and replace any
3
damaged or worn parts. Use genuine parts only. Unauthorised
parts may be dangerous and will invalidate your warranty.
Read the instructions relating to any accessory to be used
3
with this compressor. Ensure the safe working pressure of
any air appliance used exceeds compressors output
pressure. If using a spray gun, check that the area selected
for spraying is provided with an air change system/ventilation.
Ensure the air supply valve is turned off before disconnecting
3
the air supply hose.
Use the compressor in a well ventilated area and ensure it is
3
placed on a firm surface.
4.Reset Switches
5.Pressure Gauge
6.Condensate Drain Tap
SAC2276B.V2
Issue:3 (H,F) - 18/07/18

Advertisement

loading

Summary of Contents for Sealey SAC2276B.V2

  • Page 1 SAC2276B.V2 MoDEL no: Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these instructions and maintained properly, give you years of trouble free performance. IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED.
  • Page 2: Introduction And Specifications

    Anti-Vibration Feet are available as an optional extra from your must not fall below the certified thickness at any point. Sealey stockist. If to be fitted: raise the compressor using a WARNING! If an electrical fuse blows, ensure it is replaced ...
  • Page 3: Operation

    (fig.5) to the '1' position and then turn the switch on the pressure switch housing (fig.6) clockwise to position 'I'. The first motor/pump will start up followed a few seconds later fig.5 by the second motor/pump. fig.6 Original Language Version SAC2276B.V2 Issue:3 (H,F) - 18/07/18 © Jack Sealey Limited...
  • Page 4: Maintenance

    Replace oil • Check cut-out • General cleaning of compressor • Replace air filter • Check tube fittings and electrical connections • Internal & external inspection of tank Original Language Version © Jack Sealey Limited SAC2276B.V2 Issue:3 (H,F) - 18/07/18...
  • Page 5: Environment Protection

    Important: no Liability is accepted for incorrect use of this product. Warranty: Guarantee is 12 months from purchase date, proof of which is required for any claim. Sealey Group, Kempson Way, Suffolk Business Park, Bury St Edmunds, Suffolk. IP32 7AR 01284 757500 01284 703534 sales@sealey.co.uk...