Download Print this page
Sealey SAC2420E110V.V3 Quick Start Manual

Sealey SAC2420E110V.V3 Quick Start Manual

Compressor 24ltr direct drive 2hp 110v

Advertisement

Quick Links

thank you for purchasing a sealey product. manufactured to a high standard, this product will, if used according to these instructions,
and properly maintained, give you years of trouble free performance.
IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE
THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR
PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. KEEP THESE INSTRUCTIONS SAFE FOR FUTURE USE.
Refer to
Warning:
instruction
Automatic
manual
start up
1. sAFetY
i
1.1.
electricAl sAFetY
WArNiNG! It is the responsibility of the owner and the operator to read, understand and comply with the following:
You must check all electrical products before use to ensure that they are safe. You must inspect power cables, plugs, sockets and any
other connectors for wear or damage. You must ensure that the risk of electric shock is minimised by the installation of appropriate safety
devices. A Residual Current Circuit Breaker (RCCB) should be incorporated in the main distribution board. We also recommend that
a Residual Current device (RCd) is used. It is particularly important to use an RCd with portable products that are plugged into a
supply which is not protected by an RCCB. If in any doubt consult a qualified electrician. You may obtain a Residual Current device by
contacting your Sealey stockist. You must also read and understand the following instructions concerning electrical safety:
1.1.1.
The electricity at Work Act 1989 requires that all portable electrical appliances, if used on business premises, are tested by a qualified
electrician, using a Portable Appliance Tester (PAT), at least once a year.
1.1.2.
the health & safety at Work Act 1974 makes owners of electrical appliances responsible for the safe condition of those appliances and
the safety of the appliance operators. If in any doubt about electrical safety, contact a qualified electrician.
1.1.3.
ensure that the insulation on all cables and on the appliance is safe before connecting it to the power supply. See 1.1.1. and 1.1.2. and
use a Portable Appliance Tester.
1.1.4.
ensure that cables are always protected against short circuit and overload.
1.1.5.
Regularly inspect power supply cables and plugs for wear or damage and check all connections
to ensure that none are loose.
1.1.6.
importANt: ensure that the voltage marked on the appliance matches the power supply to
to be used and that the plug is fitted with the correct fuse.
do Not pull or carry the appliance by the power cable.
8
do Not pull the plug from the socket by the cable.
8
do Not use worn or damaged cables, plugs or connectors.
8
1.1.7.
Immediately have any faulty item repaired or replaced by a qualified electrician. When a
BS en 60309 plug is damaged, cut the cable just above the plug and dispose of the plug safely.
1.1.8.
Fit a new plug according to the following instructions:
a) Connect the GReen/YelloW earth wire to the earth terminal.
b) Connect the BRoWn live wire to the live terminal 'l'.
c) Connect the BlUe neutral wire to the neutral terminal 'n'.
d) After wiring, check that there are no bare wires, that all wires have been connected correctly,
that the cable outer insulation extends beyond the cable restraint and that the restraint is tight.
Note: If using a transformer to supply the compressor, it must be rated at a minimum of 2kVA to
allow the compressor to run efficiently.
1.2.
GeNerAl sAFetY
Familiarise yourself with the application and limitations of the compressor.
9
ensure the compressor is in good order and condition before use. If in any doubt do Not use the unit and contact an electrician/service
9
agent.
WArNiNG! Compressor must only be serviced by an authorised agent. DO NOT tamper with, or attempt to adjust, pressure
switch or safety valve.
Before moving, or maintaining the compressor ensure it is unplugged from the mains supply and that the air tank pressure has been
9
vented.
maintain the compressor in good condition and replace any damaged or worn parts. Use genuine parts only. Unauthorised parts may be
9
dangerous and will invalidate your warranty.
Read the instructions relating to any accessory to be used with this compressor. ensure the safe working pressure of any air appliance
9
used exceeds compressor's output pressure. If using a spray gun, check that the area selected for spraying is provided with an air
change/ventilation system.
ensure the air supply valve is turned off before disconnecting the air supply hose.
9
To move the compressor, use the handle only. maintain unit's centre of gravity when lifting. do Not attempt to lift or move the
9
compressor by any other means.
Use the compressor in a well ventilated area and ensure it is placed on a firm surface.
9
Keep tools and other items away from the compressor when it is in use, and keep area clean and clear of unnecessary items.
9
ensure the air hose is not tangled, twisted or pinched.
9
© Jack Sealey limited
compressor 24ltr direct drive 2hp 110v
model no:
Warning:
Warning:
electricity
Hot surface
Original Language Version
sAc2420e110v.v3
Wear ear
Indoor
Check oil level
protection
use only
do Not
before
open air cock
first use
before air hose
attached
SAC2420e110V.V3 Issue 1 24/05/19
Wear eye
protection

Advertisement

loading

Summary of Contents for Sealey SAC2420E110V.V3

  • Page 1 IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED.
  • Page 2: Specification

    4.6. If it is not already fitted, screw the air filter holder into the inlet port (fig.4). fig.2 fig.3 fig.4 Original Language Version SAC2420e110V.V3 Issue 1 24/05/19 © Jack Sealey limited...
  • Page 3: Operation

    Incline the compressor to ensure complete drainage. Replace the drain bolt and refill with fresh oil through the filler aperture. do Not overfill. Replace oil filler/breather (fig.3). Original Language Version SAC2420e110V.V3 Issue 1 24/05/19 © Jack Sealey limited...
  • Page 4: Scheduled Maintenance Table

    Suitable for room temperatures ranging from +5ºC to +25ºC:SeAleY CPo or equivalent SAe 40 compressor oil. Room temperature below +5ºC: SAe 20 compressor oil. WArNiNG! never mix different oils and do not use non-detergent/low quality oils as the compressor may be damaged. dispose of waste ‰...
  • Page 5: Environment Protection

    Note: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior notice. If you require documentation for alternative versions, please email or call our technical team on technical@sealey.co.uk or 01284 757505.