Download Print this page
Sealey SAC2420A.V2 Manual

Sealey SAC2420A.V2 Manual

Direct drive air compressor 4 pc air accessory kit

Advertisement

Quick Links

Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these
instructions, and properly maintained, give you years of trouble free performance.
IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE
THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR
PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. KEEP THESE INSTRUCTIONS SAFE FOR FUTURE USE.
Refer to
Wear eye
instructions
protection
protection
1.
SAFETY
1.1.
ELECTRICAL SAFETY
WARNING! It is the responsibility of the owner and the operator to read, understand and comply with the following: You must check all
electrical products before use to ensure that they are safe. You must inspect power cables, plugs, sockets and any other connectors for
wear or damage. You must ensure that the risk of electric shock is minimised by the installation of appropriate safety devices. A Residual
Current Circuit Breaker (RCCB) should be incorporated in the main distribution board. We also recommend that a Residual Current Device
(RCD) is used. It is particularly important to use an RCD with portable products that are plugged into a supply which is not protected by an
RCCB. If in any doubt consult a qualified electrician. You must also read and understand the following instructions concerning electrical
safety:
1.1.1. The Health & Safety at Work Act 1974 makes owners of electrical appliances responsible for the safe condition of those appliances and
the safety of the appliance operators. If in any doubt about electrical safety, contact a qualified electrician.
1.1.2. Ensure that the insulation on all cables and on the appliance is safe before connecting it to the power supply.
1.1.3. Ensure that cables are always protected against short circuit and overload.
1.1.4. Regularly inspect power supply cables and plugs for wear or damage and check all connections to ensure that none are loose.
1.1.5. Important: Ensure that the voltage marked on the appliance matches the power supply to be used and that the plug is fitted with the
correct fuse.
DANGER! If the power cable for this equipment is damaged, it must be replaced by the manufacturer or it's after-sales service or similarly
trained personnel to avoid danger.
DO NOT pull or carry the appliance by the power cable.
8
DO NOT pull the plug from the socket by the cable.
8
DO NOT use worn or damaged cables, plugs or connectors. Immediately have any faulty item repaired or replaced by a qualified
8
electrician.
1.1.6. Over-current Protection: The user has to make provision for the installation of the over-current protection of the power circuit in
accordance with EN 60204-1:2006.
NOTE: If using a transformer to supply the compressor, it must be rated at a minimum of 2kVA to allow the compressor to run efficiently.
1.2.
GENERAL SAFETY
Before you connect the equipment to the mains supply make sure that the data on the rating plate are identical to the mains data.
9
Familiarise yourself with the application and limitations of the compressor.
9
Ensure the compressor is in good order and condition before use. If in any doubt DO NOT use the unit and contact your Sealey
9
Stockist.
Operation must be with all guards, covers, lids and enclosures correctly in place.
9
Fully assemble the compressor before using for the first time.
9
The concentration of processed gases that can displace breathing air shall be kept within acceptable levels. Reference EN 12021 for
9
acceptable levels of contaminants in breathing air.
Remove from mains supply when performing maintenance or inspections.
9
WARNING! Item must be serviced by an authorised agent. DO NOT tamper with or attempt to adjust pressure switch or safety valve.
DO NOT carry out any welding operations on any pressurised part of the vessel.
8
Before moving, or maintaining the compressor ensure it is unplugged from the mains supply and that the air tank pressure has been
9
vented.
Maintain the compressor in good condition and replace any damaged or worn parts. Use genuine parts only. Unauthorised parts may
9
be dangerous and will invalidate your warranty.
Delivery hoses should be fitted with a safety cord.
9
It is essential to use separators, water traps and drains which process the liquids produced by the compressor system is put into
9
operation.
The compressor may only be used in suitable rooms (with good ventilation and an ambient temperature from +5°C to +40°C). Ensure there
9
is no dust, acids, vapours, explosive gases, or inflammable gases in the room. The air intake should be from a clean, outside air source.
Read the instructions relating to any accessory to be used with this compressor. Ensure the safe working pressure of any air appliance
9
used exceeds compressors output pressure.
Ensure the safe working pressure of any air appliance used exceeds compressors output pressure. If using a spray gun, check that the
9
area selected for spraying is provided with an air change system/ventilation.
Ensure the air supply valve is turned off before disconnecting the air supply hose to move a transportable compressor use the handle
9
only. Lift the compressor so that the front leg gives enough clearance for manoeuvring but maintain unit's centre of gravity in front of
the wheels. DO NOT attempt to lift or move the compressor by any other means.
Original Language Version
© Jack Sealey Limited
DIRECT DRIVE AIR COMPRESSOR
4 PC AIR ACCESSORY KIT
MODEL NO: SAC2420A.V2 SAC2420APK.V2
Wear ear
Ensure oil level
WARNING:
is correct before
High Voltage
first use
SAC5020A.V2 SAC5020APK.V2
WARNING:
WARNING:
Hot surface
Automatic
start up
SAC2420A.V2 SAC2420APK.V2 SAC5020A.V2 SAC5020APK.V2 Issue 1 15/05/24
Indoor use only
DO NOT open
Work in progress
the air cock
before an air
hose is attached

Advertisement

loading

Summary of Contents for Sealey SAC2420A.V2

  • Page 1 Before you connect the equipment to the mains supply make sure that the data on the rating plate are identical to the mains data. Familiarise yourself with the application and limitations of the compressor. Ensure the compressor is in good order and condition before use. If in any doubt DO NOT use the unit and contact your Sealey Stockist.
  • Page 2 Remove the transit plug from the oil filler aperture, pour oil into the aperture until it has reached the correct level on the sight (fig.3). Fit the oil filler/breather supplied into the aperture. Tank drain valve Original Language Version SAC2420A.V2 SAC2420APK.V2 SAC5020A.V2 SAC5020APK.V2 Issue 1 15/05/24 © Jack Sealey Limited...
  • Page 3 WARNING! Water that is allowed to remain in the tank during storage will corrode and weaken the air tank, which could cause the tank ‰ rupture. To avoid serious injury, drain the tank on a daily basis. Original Language Version SAC2420A.V2 SAC2420APK.V2 SAC5020A.V2 SAC5020APK.V2 Issue 1 15/05/24 © Jack Sealey Limited...
  • Page 4 6.5. RECOMMENDED OIL: 6.5.1. Suitable for room temperatures ranging from +5ºC to +25ºC: SEALEY CPO or equivalent use SAE 40 compressor oil. Alternately for room temperatures below +5ºC: use SAE 20 compressor oil. WARNING! Never mix different oils and DO NOT use non-detergent/low quality oils as the compressor may be damaged.
  • Page 5 DO NOT direct gauge outlet at yourself or at other persons or animals. DO NOT carry by the hose, or yank the hose from the air supply. SAC2420A.V2 SAC2420APK.V2 SAC5020A.V2 SAC5020APK.V2 Issue 1 15/05/24 Original Language Version © Jack Sealey Limited...
  • Page 6 This will enable accurate control of the gun and material refer to fig’s 9 & 10 below. fig.9 fig.10 SAC2420A.V2 SAC2420APK.V2 SAC5020A.V2 SAC5020APK.V2 Issue 1 15/05/24 Original Language Version © Jack Sealey Limited...
  • Page 7 Check for leaks from tyre connector seals, and for chafing or wear of the flexible hoses. Any problems should be immediately rectified. Note: Disconnect the air supply before attempting any cleaning or maintenance. Original Language Version SAC2420A.V2 SAC2420APK.V2 SAC5020A.V2 SAC5020APK.V2 Issue 1 15/05/24 © Jack Sealey Limited...
  • Page 8 IMPORTANT: No Liability is accepted for incorrect use of this product. WARRANTY: Guarantee is 12 months from purchase date, proof of which is required for any claim. Sealey Group, Kempson Way, Suffolk Business Park, Bury St Edmunds, Suffolk. IP32 7AR 01284 757500 sales@sealey.co.uk...

This manual is also suitable for:

Sac2420apk.v2Sac5020a.v2Sac5020apk.v2