8.7.
Removal of the Focus Motor
1. Remove the cover to the indicated by arrow (A).
2. Unscrew the 1 screw (B).
3. Unsolder (4 points).
4. Remove the focus motor.
8.8.
The
Applyment
Method
The grease apply point of lens unit are as follows.
Apply grease additionally in the specified position if necessary.
When the grease is applied, use a toothpick and apply thinly.
• Lead screw
- Grease: VFK1850 (Furoyl type)
- Amount of apply: 2 - 4 mg
• Guide pole
- Grease: VFK1829
- Amount of apply: 2 - 4 mg
31
of
Grease