8.6.
Removal of the CCD Unit
To prevent the CCD unit from catching the dust and dirt, do
not remove the CCD unit except for replacing.
8.7.
Removal of the Focus Motor
8.8.
The
Application
Method
The grease application parts of lens unit are as follows.
Apply grease additionally in the specified position if necessary.
When the grease is applied, use a toothpick and apply thinly.
• Focus motor (lead screw)/Fasten groove of nut/Guide pole
- Grease: RFKZ0472
- Amount of application: 2 - 4 mg
• Positioning pole
- Grease: RFKZ0472
- Amount of application: 1 - 2 mg
38
of
Grease