Operator Error Codes - IBM 5251 11 Maintenance Information Manual

Information display system display station
Table of Contents

Advertisement

Operator Error Codes
These errors are caused by pressing the wrong key,
pressing a key that is not recognized by the controller,
or entering the wrong data in a specified input field.
Errors appear on the display screen with the format
OOxx. The~e numbers will be blinking. To display
·the type of error, press the Help key.
If an error is displayed and no error condition is present,
the most probable cause of the error is in the controller.
Refer to the system documentation for the cause of the
erro"r.
However, yoLi can check the error conditions with the
Online Test (206). For example, the Specified Input
FielQs display (selected from the Display Verification
Menu, option 3) contains specific data fields. You can
intentionally make errors by entering the wrong data in a
field and check the error condition th·at appears.
The following list of operator error codes shows the
error code number and the description, followed by a
description of the cause of the error.
For error recovery on all these errors, press the Error
Reset key.
KBD-OOOO HELP KEY NOT ALLOWED NOW
You have pressed the Help key; however, either
no error code was displayed or the error was
issued by a program that does not support the
Help key.
KBD-OOOl LAST KEYSTROKE NOT RECOGNIZED
The controller has not kept up with the rate you
were entering information and the last character
you
ent~red
was not recognized. This is a
keyboard overrun.
KBD-0002 LAST KEYSTROKE NOT RECOGNIZED
The controller received a key code that is not valid
and does not know what key you pressed.
KBD-0003 INVALID KEY FOLLOWED CMD KEY
209
You have pressed the Cmd key but the next key
you pressed was not one of the command function
keys.
KBD-0005 CURSOR IN PROTECTED AREA OF
DISPLAY
You have attempted to enter data; however, the
cursor is not in an input field on the display. Data
cannot be entered in a protected area of the
display.
Move the cursor to a fieJd where the data can be
entered and enter the data.
KBD-0006 INVALID KEY FOLLOWED SYS REO KEY
You pressed the Sys Req key but did not follow it
by pressing either the Enter key or the Error Reset
key.
KBD-0007 MANDATORY ENTER FIELD-MUST ENTER
DATA
There is at least one mandatory enter field on the
display that you must enter data into before the
display can be changed or moved.
KBD-0008 THIS FIELD REQUIRES ALPHABETIC
CHARACTERS
The field you are now trying to enter data into will
take only alphabetic data and you have pressed a
nonalphabetic key ..
Valid characters are A through Z, blank, comma,
period, hyphen, and apostrophe. The Dup key can
be used to duplicate these characters into this
field.
KBD-0009 THIS FIELD REQUIRES NUMERIC
CHARACTERS
The field you are now trying to enter data into will
take only numeric data and you have pressed a
nonnumeric key.
Valid characters are 0 through 9, blank, comma,
period,. plus, and minus. The Dup key can be used
to duplicate these characters into this field.
KBD-0010 ONLY CHARACTERS 0 THROUGH 9
ALLOWED
The field you are now trying to enter data into will
take only signed numeric data and you have
pressed some other key.
Valid characters are 0 through 9 and the Dup key.
Maintenance Procedures
5251 MIM
1-83

Advertisement

Table of Contents
loading

This manual is also suitable for:

5250 series

Table of Contents