User Manual

2.3 Label Description

2.3.1 Label Description
Symbol
Issue 02 (2019-06-05)
Copyright © Huawei Technologies Co., Ltd.
Name
Meaning
Running
Potential hazards exist after the
warning
inverter is powered on. Take
protective measures when
operating the inverter.
Do not touch a running inverter,
Burn warning
as the shell becomes hot during
operation.
Large current
Before powering on the inverter,
warning
ensure that the inverter is
grounded because there is a
large contact current after the
inverter is powered on.
Delayed
discharge
Refer to
Reminds operators to refer to the
documentation
documents shipped with the
inverter.
Indicates the position for
Grounding
connecting the protective
earthing (PE) cable.
Operation
Do not remove the DC input
warning
connector when the inverter is
running.
Fan operation
High voltage exists after the
warning
inverter is powered on. Do not
touch the fans when the inverter
is working.
Fan replacement
Before replacing a fan,
warning
disconnect its power connectors.
2 Overview
High voltage exists after the
inverter is powered on. Only
qualified and trained
electrical technicians are
allowed to perform
operations on the inverter.
Residual voltage exists after
the inverter is powered off. It
takes 15 minutes for the
inverter to discharge to the
safe voltage.