M E N U : R E M O T E I N P U T
The device supports ten remote assignments that can trigger
specific actions like recalling a cue or preset. These events are
recalled using local contact closures, DMX In, or a specific
EtherDMX Universe / Address.
SUB MENU
DMX Map for Remote Trigger
Inputs can be remotely activated over DMX, ArtNET, or sACN. The input is activated as long
as the DMX value is at the value shown below.
Value
Action
0 – 10
Idle
11 – 20
Input 1
21 – 30
Input 2
31 – 40
Input 3
41 – 50
Input 4
51 – 60
Input 5
61 – 70
Input 6
71 – 80
Input 7
81 – 90
Input 8
91 – 100
Input 9
101 – 110
Input 10
111 – 255
Idle
OPTIONS / VALUES
Cue
1 – 99
Trigger
Cue Mode
Toggle
Netron Preset
a,b,c,...
User Preset
1 – 10
Disable DMX
Send Value
0 – 255
disabled
DMX Port
ArtNet
sACN
Universe
Source
Address
Recall a specific cue number
The cue is activated, and all times and links are
processed even if the contact is opened again
The cue is activated, and all times and links are
processed only as long as the contact is closed
Recalls this Netron preset when the contact is
closed
Recalls this user preset when contact is closed
Stops all DMX output for as long as contact is
closed
Sends specific DMX value on all ports for as
long as contact is closed
Input is disabled
1 – xx
Use DMX Port. Port must be set as Input
Artnet Trigger
sACN Trigger
Set Universe for remote trigger
Set DMX Address for remote trigger