Note several commands can be combined, but to actually send the command to the tester each
command should be terminated by a "!" character which represents a carriage return e.g.
ATS0=1!ATE1!
4.4.3

Clear Analyser Trace before Each Test

This option allows you to automatically clear the circular trace buffer before the start of each test.
This allows you to focus your problem solving on only the results of that test, rather than also being
able to see the results of previous tests and any other activity on the ISDN line.
4.4.4

Enable Sounds

By enabling this option, you will be able to hear audible confirmation that the test has completed
satisfactorily or otherwise.
Since this may be annoying in an office environment, the sounds can be turned off with this option.
4.4.5

Configure IT1000 Analyser

In this option, you can set general parameters about the IT1000, such as the length of time before it
automatically powers off and the unit's identity name. The configuration screen looks like this :
You can also defeat the auto power off circuit by unchecking the 'Auto Power Off' box. This
function is useful if you have a lot of setting up to do or you are using the unit as a terminal adaptor.
By using the Voice message option, you can change the voice message which is played during the
Voice Answering and Voice Calling tests from the factory default to a message of your choice.
The Tester Tones box allows you to change the tones played by the tester from the normal musical
notes to tones which may be more useful in a noisy environment.