18 |
Step 2 - Press F12 and ESC twice, Windows dashboard will appear.
Step 3 - Go to Internet Explorer® and navigate to C:\GVclient\SlotsEditor and
run the "SlotsEditor" executable. The interface of the editor will appear, and the
existing configuration (if any) can be imported by clicking the 'Load' button.
UCB™ Configuration
There are only a few critical aspects of the UCB™ that need to be considered
with the operation of the VE CONNECT™ : firmware version, drop sensor, single
vend mode, homing motor, and temperature (for refrigerated units only). UCB™
configuration via software will be available soon in an upcoming
software update.
Tip: for more information on the UCB™ functions and controls, refer to the UCB™
user's manual included with every REVISION™ Door or contact Vendors Exchange®
for a digital copy of the guide.
Plug in keyboard and
mouse here
Step 4 - Click the check boxes to
enable/disable slots, then click "Save"
when finished and confirm the
change. Press "Exit."
Step 5 - Press the "Windows icon" and
select "Restart" to reboot
the machine.
Step 6 - Check Pogo Mat in the
Operator Menu to confirm that
changes have taken affect.

Firmware Version

The firmware version of the UCB™ is displayed on the blue LCD display on the
inside of the machine momentarily on power up. The firmware version installed
on the UCB™ does matter for proper VE CONNECT™ operation. If you are
replacing a UCB™ or upgrading a machine with a REVISION™ Door to support VE
CONNECT™, you must ensure that the firmware version is 7.2L or higher. Refer
to the UCB™ Setup Guide for information on updating the firmware on the
UCB™. NOTE: Firmware versions may vary based on machine type
and language.
Programming the Drop Sensor
The drop sensor is a critical component in the VE CONNECT™ because
customers cannot see the physical product fall from the vending tray into the
vend bucket. There are 6 drop sensor modes on the UCB™.
Mode 00 – Off. Drop sensor is not active.
Mode 01 – Credit is returned after one attempt to vend.
The selection is not locked out.
Mode 02 – Credit returned after one attempt to vend.
Selection is locked out after 3 consecutive failures.
Mode 03 – Credit returned after 1 full cycle attempt and 5 partial turns.
The selection is locked out.
Mode 04 – Credit returned after 1 full cycle attempt and 5 partial turns.
The selection is not locked out.
Mode 05 –Credit returned after 2 full cycles if vend failed.
Selection motor stops when product fails. Use this mode for older
models that do not have a homing switch for motors.
Mode 04 is recommended for VE CONNECT™ on AP 113 and AMS.
To manually set or change the UCB™ drop sensor configuration, follow
Step 1 - Open the door and locate the UCB™ and keypad.
Step 2 - Press the "Mode" button on the UCB™ harness board located in the
corner of the board.
these steps:
| 19