(3) Cooling System

Fan Belt Tension
1. Measure the deflection (A), depressing the belt halfway
between the fan drive pulley and alternator pulley at specified
force 98 N (10 kgf, 22 lbf).
2. If the measurement is not within the factory specification, adjust
the tension adjustment screw.
Deflection (A)
Factory specification
(A) Deflection
Fan Belt Damage and Wear
1. Check the fan belt for damage.
2. If the fan belt is damaged, replace it.
3. Check if the fan belt is worn and sunk in the pulley groove.
4. If the fan belt is nearly worn out and deeply sunk in the pulley
groove, replace it.
(A) Good
Thermostat Valve Opening Temperature
1. Suspend the thermostat in the water by a string with its end
inserted between the valve and seat.
2. Heating the water gradually, read the temperature when the
valve opens and leaves the string.
3. Continue heating and read the temperature when the valve
opens approx. 8 mm (0.3 in.).
4. If the measurement is not within the factory specification,
replace the thermostat.
Thermostat's valve
opening temperature
Factory specification
Temperature at which
thermostat completely
opens
1-S16
ENGINE
7.0 to 9.0 mm
0.28 to 0.35 in.
9Y1211607ENS0012US0
(B) Bad
9Y1211607ENS0013US0
69.5 to 72.5 °C
157.1 to 162.5 °F
85 °C
185 °F
9Y1211607ENS0014US0
KiSC issued 06, 2016 A