Check Points Of Every 300 Hours; Check Point Of Every 400 Hours - Kubota GL6000A-AU-B Workshop Manual

Diesel generator
Table of Contents

Advertisement

GL6000A-AU-B, GL6000D-AU-B,GL9000A-AU-B, GL9000D-AU-B, WSM

[6] CHECK POINTS OF EVERY 300 HOURS

[7] CHECK POINT OF EVERY 400 HOURS

Check of Generator's Brush Wear
1. Check to see if the brush has worn to more than 1/2 below the
standard dimensions.
2. If wear exceeds the allowable limit, replace.
Standard
length
Brush length (Stretch out
of the Holder)
Allowable
limit
H:
Brush Length
Check of Generator's Slip-ring
1. Check to see if there is no unusual wear and surface roughness.
[GL6000A-AU-B, GL6000D-AU-B]
Factory specification
Slip-ring O.D.
Correction limit
[GL9000A-AU-B, GL9000D-AU-B]
Factory specification
Slip-ring O.D.
Correction limit
(1) Slip-ring
Replacement of Fuel Filter Element
1. Close the fuel valve (1).
2. Remove the fuel filter element (2).
3. Install the new fuel filter element, screwing it in by hand.
NOTE
• Check for fuel leak after replaced it.
(1) Fuel Valve
G-21
GENERAL
15.0 mm
All model
0.591 in.
GL6000A
-AU-B
4.5 mm
GL6000D
0.18 in.
-AU-B
GL9000A
-AU-B
7.5 mm
GL9000D
0.30 in.
-AU-B
9Y1211607GEG0032US0
49.7 mm
1.96 in.
47.5 mm
1.87 in.
64.0 mm
2.52 in.
62.5 mm
2.46 in.
9Y1211607GEG0033US0
(2) Fuel Filter Element
9Y1211607GEG0034US0
KiSC issued 06, 2016 A

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gl9000a-au-bGl9000d-au-bGl6000d-au-b

Table of Contents