[4] CHECK POINTS OF EVERY 100 HOURS

Change of Engine Oil
CAUTION
• Be sure to stop engine before changing engine oil.
1. After warming up, stop the engine.
2. Place an oil pan underneath the engine.
3. Remove the oil drain plug (1) to drain the dirty engine oil
completely.
4. Inspect the drain plug gasket. Replace it damaged.
5. Reinstall the drain plug.
6. Fill the new engine oil up to the upper line on the dipstick.
IMPORTANT
• When using an oil of different maker or viscosity from the
previous one, drain an old oil.
• Never mix two different type's of oil.
• Use the proper SAE Engine oil according to ambient
temperatures.
Refer to "4. LUBRICANTS, FUEL AND COOLANT" on page
G-10.
(1) Oil Drain Plug
Check of Battery Electrolyte Level
1. Check the battery electrolyte level.
2. If the level is below than lower level line (2), add the distilled
water to pour level of each cell.
3. If the battery can not be charged even though the electrolyte
level is correct, replace the battery.
(1) Upper Level Line
Cleaning of Air Cleaner Primary Element
1. Remove the air cleaner primary element (2).
2. Use clean dry compressed air on the inside of the primary
element (2).
Pressure of compressed air must be under 205 kPa
2
(2.1 kgf/cm
, 30 psi).
Maintain reasonable distance between the nozzle and the filter.
NOTE
• The air cleaner uses a dry element. Never apply oil to it.
• Be sure to refit the dust cup with arrow ↑ (on the rear)
upright. If the dust cup is improperly fitted, dust passes by
the dust cup and directly adheres to the element.
• Do not run the engine with filter element removed.
• Change the primary element once a year or every 6th
cleaning.
• Do not touch the secondary element (1) except in cases
where replacing is required.
(1) Secondary Element
G-18
GENERAL
[A] GL6000A-AU-B, GL6000D-AU-B
[B] GL9000A-AU-B, GL9000D-AU-B
9Y1211607GEG0011US0
(2) Lower Level Line
9Y1211607GEG0012US0
(2) Primary Element
9Y1211607GEG0027US0
KiSC issued 06, 2016 A