Download Print this page

Installation Instruction - AEG BSK882320M Installation Manual

Hide thumbs Also See for BSK882320M:

Advertisement

Installation Instruction

EN
Warning! Before proceeding with installation, read
the safety information in the User Manual.
The oven is designed to be connected to 230 - 240V
~ (50Hz) electricity supply.
The oven has an easily accessible terminal block which
is marked as follows:
Letter L - Live terminal
Letter N - Neutral terminal
- Earth terminal
CAUTION!
This oven must be earthed!
The cable used to connect the oven to the electrical
supply must comply to the specifications given below.
For UK use only
Connection
Min. size
via
Cable/flex
Cooker
2,5 mm²
Control
Circuit
It is necessary that you install a double pole switch
between the oven and the electricity supply (mains),
with a minimum gap of 3 mm between the switch con-
tacts and of a type suitable for the required load in com-
pliance with the current regulations.
The switch must not break the yellow and green earth
cable at any point.
2
Cable/flex
Fuse
type
PVC / PVC
min: 15 A
twin and
max: 20 A
earth
5
1
After installation and connecting, the cable must
be placed so that it cannot at any point reach a
temperature of more than 50°C above the
ambient temperature.
Before the oven is connected, check that the
main fuse and the domestic installation can
support the load; and that the power supply is
properly earthed.
The manufacturer declines any responsibility
should these safety measures not be carried out.
Attention: The new appliance may only be installed and
connected by a registered expert.
Please comply with this. If you do not, any
damage resulting is not covered by the warranty.
Safety information for the installer
• The electrical installation is to be set up so
that the appliance can be isolated from the
mains with a minimum 3 mm all-pole contact
separation.
• Suitable separation devices include e.g.
cut-outs, fuses (screw fuses are to be taken
out of the holder), RCD's and contactors.
• Anti-shock protection must be provided by the
installation.
• The built-in unit must meet the stability
requirements of DIN 68930.
• Built-in ovens and built-in cooking surfaces
are fitted with special connection systems.
For safety reasons, they must only be
combined with appliances from the same
manufacturer.

Advertisement