Correct Use; Scope Of Delivery; Technical Data - GEM 52 Installation, Operating And Maintenance Instructions

Solenoid valve, plastic
Table of Contents

Advertisement

Available languages

Available languages

3

Correct use

WARNING
Use the solenoid valves only for the
intended purpose!
Otherwise the manufacturer liability and
®
guarantee will be void.
The solenoid valve to be used
G
exclusively within permissible
limits and in consideration of these
installation, operating and maintenance
instructions. Any other use is to be
considered not as intended.
The solenoid valve is not approved for
G
explosion endangered areas.
The GEMÜ 52, 102, 202 solenoid valves
must
only be used for the control of media

which do not attack, chemically or
mechanically, the materials used,
be operated above freezing point with

freezable media,
only be used within the performance

limits (see chapter 5 "Technical data" and
the details in the data sheet),
not be modifi ed from a constructional

point of view.
The component must be installed
in accordance with the EMC
requirement for the plant.
4

Scope of delivery

The following is included in the scope of
delivery:
Solenoid valve with solenoid coil

Connector plug

Installation, operating and maintenance

instructions
5

Technical data

Working medium
Corrosive, inert, gaseous and liquid media which have no
negative impact on the physical and chemical properties of
the body and seal material.
Perm. temperature of working medium
PVC-U (Code 1)
PVDF (Code 20)
Ambient conditions
Max. permissible ambient temperature
General information
Protection class acc. to EN 60529
Directives
Pressure Equipment Directive
Low Voltage Directive
EMC Directive
Applied standards
Radio interference voltage
148.5 kHz...30 MHz
150 kHz...30 MHz
Cable gland
PG 11
Approvals
UL approval
UR (recognized)
Rating
Continuously rated
Electrical data
Power supply*
Supply voltage
(±10 %)
24 V AC
120 V AC
230 V AC
12 V DC
24 V DC
Electrical power consumption
Pull in / hold in (with UL approval)
AC voltage
Typ 52
DN 2 - 6
Typ 102
DN 6 - 10
Typ 202
DN 10 - 15
DC voltage
Typ 52
DN 2 - 6
Typ 102
DN 6 - 10
Typ 202
DN 10 - 15
* Permissible voltage tolerance to VDE 0580
15/24
10 to 60 °C
-20 to 100 °C
40 °C
IP 65
97/23/EC
2006/95/EC
2004/108/EC
EN 55014:1993
EN 55011:1991
Y10Z2
Mains frequency
50/60 Hz
50/60 Hz
50/60 Hz
-
-
6.0 W (7.45 W)
9.0 W (8.45 W)
14,0.W (15.25 W)
6.0 W (7.45 W)
9.0 W (8.45 W)
14.0 W (15.25 W)
52, 102, 202