Door Disassembly - Frigidaire CGMV173KB Servicing

Hide thumbs Also See for CGMV173KB:
Table of Contents

Advertisement

NOTE
After any service to the door:
1. Make sure that door sensing switch and secondary
interlock switch are operating properly. (Refer to
section 3 "Test Procedures".).
2. An approved microwave survey meter should be
used to assure compliance with proper microwave
radiation emission limitation standards.
After any servicing, make sure of the following:
1. Door latch heads smoothly catch latch hook through
latch holes and that latch head goes through center
of latch hole.
2. Deviation of door alignment from horizontal line of
cavity face plate is to be less than 1.0mm.
3. Door is positioned with its face pressed toward
cavity face plate.
4. Re-install outer case and check for microwave
leakage around door with an approved microwave
survey meter. (Refer to Microwave Measurement
Procedure.)
NOTE
The door on a microwave oven is designed to act as an
electronic seal preventing leakage of microwave energy
from oven cavity during cook cycle. This function
does not require that door be air-tight, moisture-tight
or light-tight. Therefore, occasional appearance of
moisture, light or sensing of gentle warm air movement
around oven door is not abnormal and does not indi-
cate a leakage of microwave energy from oven cavity.
Upper Door
Hinge P in
Upper Oven
R E -INSTALL
Hinge
Door assembly
Lower Door
Latch
Hinge P in
Heads
R E -INSTALL
Figure 4-9. Door Components
Hood E xhaust Louver
Lower
Oven Hinge
Door Stopper
Section 4 Component Teardown

Door Disassembly

Removal
1. Disconnect the power supply cord and remove the
oven from wall and remove outer case. (Refer to
procedure of "Removal of Oven from Wall" and
"Outer case Removal")
2. Open the door and block it open.
3. To discharge high voltage capacitor, wait for 60
seconds.
4. Remove the hood exhaust louver from the oven
cavity. (Refer to the procedure of "HOOD EXHAUST
LOUVER REMOVAL".)
5. Remove door assembly, refer to "Door Replacement"
Replacement of door components are as follows:
6. Place door assembly on a soft cloth with latches
facing up.
NOTE
As engaging part of choke cover and door frame are
provided at 15 places, do not force any particular part.
Choke Cover
7. Insert a putty knife (thickness of about 0.5mm)
into the gap A between the choke cover and door
stopper and between the choke cover and the door
frame as shown Figure 4-10 to free engaging parts.
8. Pry the choke cover by inserting a putty knife in
order shown in Figure 4-10.
9. Now choke cover is free from door panel and door
frame.
Door Frame Assembly
10. Remove four (4) screws holding the door panel to
the door frame assembly.
11. Release door panel from the door frame assembly.
NOTE
It is easier to release the engaging parts of the upper
or lower door hinge pin side at first.
12. Now, door frame assembly is free.
4-13

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cgmv174kfCgmv173kw

Table of Contents