Waterproof self testing maintained emergency luminaire

Advertisement

and the capacitors should be connected and
fully charged. If the capacitor is not fully
charged, the test is postponed until the
capacitor is completely charged.
Back Up Operation
The capacitor's autonomous duration during
emergency mode is at least the one that is
stated in the list of the technical characteristics.
During emergency mode, a LED strip test is
also performed.
Resetting Errors
Push the TEST/RESET button (page 3) for >10
seconds, to delete all the indicated LED errors .
Then
the illumination sign enters regular
operation mode.
Test switch
Pressing the test switch less than 5 seconds
will initiate a light source test (last for 3 secs).
Pressing the test switch between 5 to 10
seconds will initiate a manual capacitor
duration test. This test will not be started if the
capacitor is not fully charged (i.e. If the green
LED is flashing). If the test switch is pressed for
Status of LEDs
Description
LEDs
Normal
Charging
Charger's fault, capacitor not connected or mains off
Capacitor's duration test (auto or manual)
Capacitor's fault
Light source test
Light source fault
Capacitor's fault and light source fault
Charger and capacitor's fault (or mains off and capacitor fault)
Charger and light source fault (or mains off and light source fault)
Charger, capacitor and light source fault (or mains off, capacitor and light source fault)
Led status explanation
Continuous ON
Continuous OFF
Page 2 from 4
more than 10 seconds, the illumination sign will
be reset (delete all errors).
ΑΤΤΕΝΤΙΟΝ!!!
1. Operations for installation, maintainance or
testing must be done by authorized personel
only.
2. The luminaire must be connected to the
mains power supply thru a fuse dependent by
the total amount of the line's power load.
3.In case of capacitors or lamp replacement,
these must be replaced by parts of the same
type, by the manufacturer or by a competent
person.
4. In case of inactive use for a period greater
than 2 months, disconnect the capacitor by
pulling out the connector when is fully charged.
5. I s not allowed to discard capacitors in to
t i
common trash bins, they must be
d i s c a r d e d o n l y
i n c a p a c i t o r 's
recycling points. Do not incinerate.
Flashing at 1,2 Hz
923900000_09_010
INSTALLATION INSTRUCTIONS
1
2
L1 L N
4
5
7
8
For wall or ceiling installation
Step 1. Remove the diffuser. Place a flat blade screwdriver and pull up gently the reflector.
Step 2. Install the included plastic cover in to the unused hole and install the base plastic (with the
included mounting screws and plugs).
Step 3. Always use in any case round mains cable, with external diameter of 6-9mm (H05RN-F
type 2x1mm² or any other type, at least equal to it's mechanical and electrical properties).
ATTENTION!! The cable must not be deformed in any way (This requirement is important
to ensure the tightness isolation IP 65). Install the cable gland, pass the round cable through
and tighten it all the way.
Step 4. Place the capacitor's connector to the corresponding connector on the P.C.B.
Step 5. Connect the mains cables to the respective terminal block (connect the ground wire). Ν for
neutral, L for live wire and L1 for the maintained operation. The L1 wire can be connected to an
external switch to control the maintained or non maintained operation of the luminaire. For permanent
maintained operation use two wires to power the luminaire, Ν for neutral and L for live wire, and link
the L and L1.
Step 6. Install the included tie (if needed) to fasten securely the power cables.
Step 7. Refit the reflector and fasten the two small screws (included).
Step 8. Finally place the diffuser by using the 4 screws (tightening torque 1.2Nm).
Step 9. Manual TEST or Resetting Errors
In order to test or reset the device you must carefully remove the diffuser by unfastening the 4
mounting screws. Then push the button as described in the according paragraphs on page 1 and
2.
NOTE!!
After finishing the installation you must power the luminaire at least for 3 hours for
capacitor charging to perform the nominal autonomy.
Page 3 from 4
3
6
9
923900000_09_010