Central Machinery 42289 Assembly & Operating Instructions page 5

34" radial bench drill press

Advertisement

Brought to You by Augusta Flint
Step 3)
Connect each set of Legs (#24C) by attaching a Front Bar (part #25C) across the
middle of the unsupported Legs. Insert one Bolt (#23C) at each end and tighten
it into place with Nut (#22C). Repeat for the opposite set of Legs.
Step 4)
Attach the Front Panel (part #27C) to the top of the Legs currently without a top
panel. Line up the holes in the Front Panel (#27C) with the holes in each Leg (#24C).
Insert Bolt (#23C) through the holes and tighten on the Front Panel with Nut (#22C).
Repeat for the last set of Legs.
Base-Column-Table
Step 1)
Remove any protective sleeves from the Base (part #6C) and the Column (part #1C).
With the Base (part #6C) on a flat level surface, place the Column Support (part #4C)
on the Base making certain that the holes are aligned.
Step 2)
Locate the four (4) 8mm x 20mm Hex Bolts (part #5C). Insert one (1) Bolt through
each hole in the Column Support (#4C) and through the Base (#6C). Firmly
tighten all four (4) Bolts.
Step 3)
Loosen the Screw (part #11C) in the Column Collar (part #19C) using the 3 mm Hex
wrench supplied. Remove the Column Collar (#19C) and Rack (part #2C) from the column.
Step 4)
Locate the Worm Elevation gear (part #18C). Insert the Worm-Elevation gear (#18C)
into the Table Support (part #7C). Insert the Worm Elevation as far into the opening as is
possible.
Step 5)
Locate the Crank (part #8C). The Crank (part #8C) is to be installed on the Worm Elevation
(part #18C). You may need to loosen the Screw (#11C). Get the Crank as close as possible
to the Table Support (#7C) , and then tighten the Screw (#11C).
Step 6)
As necessary, locate the Rack (part #2C) and with the smooth end of the Rack (#2C) pointing
upward-see Figure 1. Slide it down through the opening in the Table Support (part #7C).
Engage the Rack into the Gear Mechanism found on the inside opening of theTable Support.
Figure 1 - Rack
Step 7)
While holding the Rack (#2C) and the Table Support (#7C) together (as assembled in the
previous steps), slide the entire assembly down over the Column (#1C). Slide the
Rack down the Column until the Rack is touching the Column Support (part #4C)
at the Base.
Step 8)
Replace the Column Collar (part #19C), with the bevel side down, which was
removed in Step 3. Tighten it with the Hex wrench used in Step 3 .
Note:
Only tighten the Screw (#11C) enough to keep the Collar in place. Over tightening the Screw
may result in breaking of the Column Collar (#19C).
#42289
Column Collar (#19C)
Rack (part #2C)
Crank (#8C)