O-Ring Seals; Kit For Sanitisation/Decalcification And Filter Change - Happy Frizz ZERO Use And Maintenance Manual

Filter, soda maker and refrigerating system for water
Table of Contents

Advertisement

Insert the inclined bottle,
Press the button until you
twisting it into the ZERO
hear a venting noise.
system.
Repeat as many times as
you wish to create sparkling
ATTENTION:
After carbonating the water it is mandatory to
vent the excess gas, tilting the bottle forward,
before unscrewing it. Otherwise the pressure
accumulated inside the bottle can damage the
appliance.

O-RING SEALS:

For the operation of the appliance, there must be a seal between the
cylinder support and the cylinder valve itself.
It is located in the gas cylinder housing. Otherwise, in the absence of it, a
gas leak and/or water leak would occur during the gasification process.
If you have lost the seal, you can purchase one separately (see page
- 32).
Bring the bottle towards
you by tilting it, thus
allowing the excess gas to
escape.
water.
Unscrew the bottle.
We recommend using cold water
because at low temperatures the water will
carbonate better.
20
KIT FOR SANITISATION/DECALCIFICATION
AND FILTER CHANGE
WHEN TO PURCHASE IT:
> When prompted by your ZERO system (1,500 L/6 months)
> After 1 week of inactivity (less than 0.8L of water supplied)
> If an additional filter change is required (little water comes out of the dispenser
due to the composition of the incoming water).
WHAT THIS PACK CONTAINS:
> 1 new filter HAPPY FRIZZ ZERO Microfiltration 0.5 MICRON.
> 1 sanitising/descaling sachet 12.5 g HAPPY FRIZZ SaniKit.
WHY YOU NEED THIS KIT:
> To sanitise your ZERO system;
> To decalcify the entire circuit of the system;
> To replace the used filter with the new one, guaranteeing the quality of the
water you drink.
FILTER CHANGE PREPARATION
If you are about to use this pack, it means that your ZERO system has requested a filter change, after
sanitising the system; or, due to the composition of the incoming water, you need an additional filter change.
Before replacing the used filter with the new one, make sure you have completed the assisted sanitation
process. If you have opted for an additional filter change, periodic sanitisation will not be necessary as it is
not required by your ZERO system so it is sufficient to remove the old filter and to replace it with the new one.
WARNINGS:
> Do not re-use the used filter.
> Do not insert a new filter if the sanitisation procedure has not been performed (if requested by your ZERO
system).
> Your Happy Frizz ZERO system is a water treatment device for human consumption. The quality of the
water you drink can only be guaranteed if the periodic sanitisation/decalcification is carried out. The
ZERO system is designed to accompany you step by step in this activity.
BEFORE STARTING THE SANITISATION/DECALCIFICATION PROCEDURE
ATTENTION:
IF YOU ARE NOT READY TO CARRY OUT THE PROCEDURE AND YOU DO NOT HAVE WITH
YOU A SUITABLE 3L CONTAINER, DO NOT START THE SANITISATION DECALCIFICATION PROCEDURE.
IF THE APPLIANCE WAS INSTALLED AT THE WATER MAINS IT IS VERY IMPORTANT TO
CLOSE THE WATER FLOW AND THEN THE "T" VALVE (as shown in the photo)
OPEN
CLOSED
21

Advertisement

Table of Contents
loading

Table of Contents