TEMPERATURE CUSTOMISATION:
The user can adjust the water temperature differently than the automatic pre-set temperature (10°C), to
between a minimum of 6°C and a maximum of 30°C. The temperature adjustment buttons and the relative
indicator are not normally active (stand-by after 20 s). Pressing an active area ofthe display, the + and -
buttons come on. Pressing the buttons changes the SET temperature, which is stored.
We recommend setting the temperature between 8 and 12 degrees. This is the IDEAL TEMPERATURE
range that allows you to have cold water, reduced consumption and longevity of your ZERO system.
STAND BY - ZERO ECO MODE
After 90 seconds of inactivity of the machine (end of operations in progress, including internal tank refill, and
not pressing a button), the display goes into stand-by (display lights deactivated in fading).
Pressing the active parts of the display the machine exits stand-by, turning the dispensing buttons and the
temperature regulator back on. The temperature controller goes into standby after 20 s.
The temperature regulator does not exit stand-by in the event of the dispensing buttons being pressed. This
is due to the splitting of the display into two areas: dispensing buttons area and temperature regulation area
(to exit the temperature regulator from stand-by, press in the right area).
HOW TO INSTALL THE ZERO SYSTEM ON THE NETWORK
NETWORK CONNECTION KIT INSTALLATION
ZERO for your convenience can also be installed directly to the home network thanks to the installation kit.
Visit the website www.happyfrizz.it for further information.
ONLY INSTALL ZERO WITH THE ZERO INSTALLATION KIT. This kit alone, in addition to facilitating
installation, ensures perfect operation of your ZERO. Failure to use this kit will void the product warranty.
Carefully read the instructions in the user manual of the ZERO network installation kit.
Once installed, proceed as follows.
ATTENTION:
the machine water inlet pressure must not exceed 5 bar and must not be less than 2 bar.
TRANSFER FROM WATER TANK (only if it is installed on the network)
The transition from "tank" to "water network" takes place in this manner:
→ Press the sanitisation button for 5 s (button off), the natural water
button starts flashing;
→ Press the natural water button, the natural water button turns off and
the sanitisation button starts flashing;
→ Press the sanitisation button for 5 seconds to confirm switching to the water network.
At the end of the sequence open the shut-off valve.
Once the network system is connected, we recommend that you empty
the external tank, dry it with a cloth and put it back in place on the ZERO.
You can use the external tank during the sanitisation/descaling procedure.
ATTENTION:
once connected to the network, check that there are no leaks
along the path of the connection pipe and check that the same pipe is not
compressed or narrowed caused by excessive bending of the pipe.
OPEN
The change from tank to the water network is also possible with an empty external tank (barred drop light
on). The customised calibration times that may have been set are reset to the default values.
In the event of an incomplete sequence (exceeding the maximum time for completing the sequence)
nothing happens.
The sequence is not possible with the sanitisation indicator on (ZERO gives precedence to this activity).
5 SEC.
18
PASSAGE FROM WATER NETWORK TO TANK (only if previously installed on the network)
Close the "T" shut-off valve.
The transition from "water network" to "tank" takes place in this way:
→ Press the sanitisation button for 5 s (button off), the natural water
button starts flashing;
→ Press the natural water button, the natural water button turns off
and the sanitisation button starts flashing;
→ Press the sanitisation button for 5 seconds to confirm switching to
the tank.
I tempi di taratura personalizzata eventualmente impostati vengono
riportati ai valori di default e non a quelli precedentemente
impostati.
The customised calibration times that may have been set are reset to
the default values and not to those previously set.
In the event of an incomplete sequence (exceeding the maximum time
for completing the sequence) nothing happens.
The sequence is not possible with the sanitisation indicator on (ZERO
gives precedence to this activity.
ANTI-LEAK DEVICE
The ZERO system is equipped with a water leak detector. In the event of internal water leaks the machine
goes into "safety lock" mode and the maintenance light (wrench) is activated on the display.
In this case it is advisable to disconnect the ZERO system power socket for 10 hours. If the machine is
connected to the water mains, close the "T" valve.
After 10 hours, reconnect the power socket and, if connected to the water supply, open the "T" valve.
If the problem is not resolved, contact support.
MACHINE INACTIVE FOR A LENGTHY PERIOD
If the machine is not used for more than a week (dispensing less than 0.8 litres) after the first activation by
the end user, the sanitisation button will light up with the possibility for the end user to carry out the same.
The calculation of the week is given by the comparison between the time counter for replacing the filter and
the litre counter. The constraint is valid both when the machine is powered by electricity and when it is not
(in this case the sanitisation button lights up together with the next activation).
PROCEED WITH SANITATION (page 22)
HOW TO CARBONATE THE WATER
1. Before creating the carbonated water, fill the carbonating bottle with cold water up to the filling line.
2. Insert the bottle into the holder and twist. To facilitate twisting, pull the tube towards you to tilt the block.
Reposition the bottle in vertical position pushing it backwards (towards the body of the ZERO system).
3. Press the button on the head of the ZERO system, repeatedly for the desired carbonation level, maximum
3 or 4 short but firm pressures.
4. Once satisfied with the level of carbonation, pull the bottle towards you to unscrew it. Done!