4. Appliance description CPM-1-70 / CEW-1-200
The dimensions and design of the buffer module CPM-1-70 are tailored to
the Wolf heat pump range, enabling variable combination.
The CPM-1-70 is supplied ready for connection as a separating cylinder or
cylinder in series. It is designed to provide optimum evaporator defrosting, in
particular for the BWL-1 air/water heat pumps.
When connected as a separating cylinder, it also acts as a low loss header.
A class A high-efficiency heating circuit pump and three-way diverter valve
for DHW heating are already installed inside the casing, including the
necessary pipework, ready for connection. Type CPM-1-70/7 with 7m pump
and type CPM-1-70/8 with 8m pump.
The PU rigid foam insulation ensures minimum radiation and standby heat
losses.
A pre-installed, thermally insulated safety assembly is supplied for on-site
installation.
Standard delivery CPM-1-70
Packaged in box, fully encased,
class A high-efficiency pump and
3-way diverter valve with all necessary pipework,
ready to connect, incl. installed boiler drain & fill valve,
adjustable feet, installed sensor well and vent valve;
safety assembly and connecting cable for 3-way diverter valve
and high-efficiency pump provided,
connecting pipe for separating cylinder version with heat pump
return flow included,
installation instructions included.
CEW-1-200 DHW cylinder with internal indirect coil.
Steel cylinder with corrosion protection provided by special enamelled
coating on the inner wall of the cylinder, compliant to DIN 4753. Additional
corrosion protection provided by sacrificial magnesium anode. DHW cylinder
for DHW heating in conjunction with a heat pump.
Suitable for systems to DIN 1988, EN 12828 and DIN 4753.
Dimensions and design are tailored to the Wolf heat pump range, enabling
variable combination.
The DHW cylinder is equipped with a highly efficient bare-tube heat
exchanger with indirect dual coil for convenient DHW heating.
The PU rigid foam insulation ensures minimum radiation and standby heat
losses.
Standard delivery
Packaged in box, fully encased, ready for
connection, incl. installed boiler drain & fill valve,
adjustable feet and installed sensor well;
installation instructions included.